P70CA-2C 50/450#, 1/4 MALE FLARE
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70DA-1C 50/450# M/R OPEN-HI 36",# SW.
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170AA-118C 100/400# PSIG 5 BU DIFF. ADJ.35/200# PSI
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70AA-118C 100/400# DIFF. ADJ.; 35/200# 36CAP; 13
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70MA-2C FOR AMMONIA; 20/100 PSIG LS 15 RANGE 100/425 PSIG HS
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170LB-6C 12/80 PSIG LS S BU RANGE 100/425 PSIG HS;
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70LB-6C 20/80 PSIG LS 13 36 RANGE 100/425 PSIG HS; W/KNOB
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170MA-1C MAN RESET HS
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170LB-1C PRESSURE CONTROL; 20"/100 PSIG LS 5 BU RANGE 100/425 PSIG
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70MA-1C SPST DUAL PRES. CONTROL; 20"/100#; 100/425# 36" CAP
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70LB-1C SINGLE POLE DUAL PRESS, SPST, 20" WE TO 100 PSI LOW PRESS.100 PSI TO 500 PSI HIG
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70CA-1C PRESSURE CONTROL, SPST 20IN/100P
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70AB-2C 20"/100# 36"CAP OPEN-LO # SW.
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170AB-12C PRESSURE CONTROL, 12 IN. to 80 PSI, 1/4 IN. MALE FLARE CONN.
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70AB-12C SPST PRESSURE CONTROL; 12"/80# 1/4"FLARE 36" CAP
The P70 and P170 Controls for low pressure applications are designed primarily for low pressure cut-out control, pump-down control, and capacity control on commercial refrigeration and air conditioning applications.
A421ABD-02C ELECTRONIC SINGLE STAGE
The A421 Series Electronic Temperature Controls are single-stage controls with a single-pole, double-throw (SPDT) output relay. A421 Controls feature a bright backlit LCD with adjustable brightness and a three-button touchpad interface that can be set up to restrict user adjustments. An LED indicates the output relay's On/Off status. Standard A421 Series control modules have simple On and Off temperature settings for heating or cooling, an adjustable anti-short cycle delay, temperature setback, and sensor offset capability. The temperature control range is -40 to 212°F or -40 to 100°C. The A421 controls are available either in Type 1 (NEMA), IP20 (CE), high-impact plastic enclosures suitable for surface or DIN rail mounting or in Type 4X (NEMA), IP67 (CE) watertight, corrosion resistant surface mount enclosures.

The A421 Electronic Temperature Control can be used to control a wide variety of single-stage refrigeration or HVAC equipment.Sample temperature control applications can be found inside the product data sheet.

A421ABC-02:
Type 1 (NEMA), IP20 standard enclosure for DIN rail and surface-mount applications. Rated for 120/240 VAC. Includes an A99BB-200C temperature sensor with 6 ft 7-1/5 in. (2.0 m) cable
A421AEC-01C ELECTRONIC SINGLE STAGE, 120/240 VAC, 4X, SPDT, 9" Temp.Sensor
The A421 Series Electronic Temperature Controls are single-stage controls with a single-pole, double-throw (SPDT) output relay. A421 Controls feature a bright backlit LCD with adjustable brightness and a three-button touchpad interface that can be set up to restrict user adjustments. An LED indicates the output relay's On/Off status. Standard A421 Series control modules have simple On and Off temperature settings for heating or cooling, an adjustable anti-short cycle delay, temperature setback, and sensor offset capability. The temperature control range is -40 to 212°F or -40 to 100°C. The A421 controls are available either in Type 1 (NEMA), IP20 (CE), high-impact plastic enclosures suitable for surface or DIN rail mounting or in Type 4X (NEMA), IP67 (CE) watertight, corrosion resistant surface mount enclosures.

The A421 Electronic Temperature Control can be used to control a wide variety of single-stage refrigeration or HVAC equipment.Sample temperature control applications can be found inside the product data sheet.
A19ABC-24C REMOTE BULB TEMPERATURE CONTROL
-30/100F, DIFF 3 - 12 ADJ, 8' CAP, SPDT, NEMA 13/8 X 4 BULB

These thermostats are available with fixed or adjustable differential.
The various control ranges cover a broad range of temperature applications with a minimum number of models.
On request a built-in high or low limit stop is possible and can be adjusted quickly and easily in the field.
All models have a universal way of adjustment.
For this purpose a knob and sealing cap are enclosed.
All are equiped with IP30 enclosure
A19ABA-40C REMOTE BULB TEMPERATURE CONTROL
DIFF 3-12 ADJ,6' CAP, SPST, NEMA 1,3/8 X 4 BULB, OPEN LOW

These thermostats are available with fixed or adjustable differential.
The various control ranges cover a broad range of temperature applications with a minimum number of models.
On request a built-in high or low limit stop is possible and can be adjusted quickly and easily in the field.
All models have a universal way of adjustment.
For this purpose a knob and sealing cap are enclosed.
All are equiped with IP30 enclosure.
A421ABC-02C ELECTRONIC SINGLE STAGE
Features
Features A421 Standard model
Control Front Panel LCD:
Displays the temperature, parameters, and status and allows you to adjust the backlight intensity for ambient light conditions. Custom icons display the system and control status.
Basic and Advanced Programming Menu:
Provides two levels of parameter adjustment and control setup, allowing you to set up advanced features in one menu and easily adjust basic parameters in the other menu.
On/Off Temperature Adjustment:
Allows you to select the temperature values at which the relay turns On and Off, which automatically defines the Heating or Cooling mode of operation.
Switch-Activated Temperature Setback:
Allows you to shift the On/Off temperature by an adjustable setback value. When a user-supplied switch closes the binary input control circuit, the control operates at the defined setback temperatures.
Adjustable Anti-Short Cycle Delay:
Allows you to select the minimum time the output relay remains off before the next on cycle; avoiding short cycling, hard starts, and nuisance overload outages on compressors and other inductive applications.
Adjustable Sensor Offset:
Allows you to adjust the displayed temperature to the actual sensed temperature.
Optional Restricted Adjustment Mode:
Allows you to restrict the On/Off adjustment to your defined temperature range.
Sensor Failure Mode:
Allows you to select the relay On/Off state in the event of a sensor or sensor wire failure.
Backlight Brightness Level:
Allows you to adjust the LCD backlight intensity.
Extra Features A421 Defrost model
Off-Cycle Defrost:
Allows you to shut off the refrigeration system for defined defrost time interval and frequency. You can also start or stop a manual only defrost offcycle.
Extra Features A421 Timer model
Free-Cooling and Ventilation:
Allows you to adjust for free-cooling and timed-ventilation, and provides over-cooling protection.
A421GBF-02C ELECTRONIC SINGLE STAGE
Features
Features A421 Standard model
Control Front Panel LCD:
Displays the temperature, parameters, and status and allows you to adjust the backlight intensity for ambient light conditions. Custom icons display the system and control status.
Basic and Advanced Programming Menu:
Provides two levels of parameter adjustment and control setup, allowing you to set up advanced features in one menu and easily adjust basic parameters in the other menu.
On/Off Temperature Adjustment:
Allows you to select the temperature values at which the relay turns On and Off, which automatically defines the Heating or Cooling mode of operation.
Switch-Activated Temperature Setback:
Allows you to shift the On/Off temperature by an adjustable setback value. When a user-supplied switch closes the binary input control circuit, the control operates at the defined setback temperatures.
Adjustable Anti-Short Cycle Delay:
Allows you to select the minimum time the output relay remains off before the next on cycle; avoiding short cycling, hard starts, and nuisance overload outages on compressors and other inductive applications.
Adjustable Sensor Offset:
Allows you to adjust the displayed temperature to the actual sensed temperature.
Optional Restricted Adjustment Mode:
Allows you to restrict the On/Off adjustment to your defined temperature range.
Sensor Failure Mode:
Allows you to select the relay On/Off state in the event of a sensor or sensor wire failure.
Backlight Brightness Level:
Allows you to adjust the LCD backlight intensity.
Extra Features A421 Defrost model
Off-Cycle Defrost:
Allows you to shut off the refrigeration system for defined defrost time interval and frequency. You can also start or stop a manual only defrost offcycle.
Extra Features A421 Timer model
Free-Cooling and Ventilation:
Allows you to adjust for free-cooling and timed-ventilation, and provides over-cooling protection.


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.