AS WE WORK HARD ON OPENING OUR IN-PERSON HVAC STORE, WE’RE EXCITED TO ANNOUNCE OUR ONLINE SHOP IS LIVE!

For now, we’ve carefully selected HVAC products to get you started. Our inventory will expand, so stay tuned for more options as we grow! Thank you for being part of our journey. 🚀


1820-019 PG9 REPLACEMENT PILOT UNI-KIT 90° LEFT HAND 36" (91CM)
The Robertshaw® 1820 Series Pilot Uni-Kit® models are designed to replace hard-to-find ITT-General PG9 type pilots. A special 1/4” tubing adaptor is typically provided with nut and ball sleeve. Uni-Kits are available with and without a 32” (810mm) thermopile.

Features and Benefits

Many flame pattern types available
Thermocouple or thermopile options
Spark electrode available
Horizontal or vertical gas inlet
Several mounting bracket types available
Aerated pilots with non-linting characteristics
Login to Access Pricing 0.0 CAD
1820-009 PG9 REPLACEMENT PILOT UNI-KIT 90° RIGHT HAND 36" (91CM)
The Robertshaw® 1820 Series Pilot Uni-Kit® models are designed to replace hard-to-find ITT-General PG9 type pilots. A special 1/4” tubing adaptor is typically provided with nut and ball sleeve. Uni-Kits are available with and without a 32” (810mm) thermopile.

Features and Benefits

Many flame pattern types available
Thermocouple or thermopile options
Spark electrode available
Horizontal or vertical gas inlet
Several mounting bracket types available
Aerated pilots with non-linting characteristics
Login to Access Pricing 0.0 CAD
1980-012 1980 SNAP-FIT THERMOCOUPLE 12" (30CM)
The Robertshaw® 1900 Series Thermocouples include either a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. It is also found on many LP gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame. The Robertshaw 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits
Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-072 1980 SNAP-FIT THERMOCOUPLE 72" (182CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-060 1980 SNAP-FIT THERMOCOUPLE 60" (152CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1960-027 LOW MASS THERMOCOUPLE 27" (68CM)
The Robertshaw® 1960 Series Thermocouple is a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. It is also found on many LP gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame.

ATTENTION: The 1960-027 has standard thermocouple threads, and WILL NOT fit applications with metric threads.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1970-018 UNI-COUPLE 20 TO 30 MILLIVOLTS THERMOCOUPLES 18" (45CM)
The Robertshaw 1970 Series Thermocouple Uni-Couple® design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermocouple's rolled threads for proper positioning in every application.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1950-532 1950 & 1951 THERMOPILES 36" (91CM)
Robertshaw® thermopiles are the industry leader for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output. Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors.

The 1950 thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 thermopiles, also known as CP-2 (500-600 millivolts) are coaxial connectors.

The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices.

Features and Benefits
Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1970-024 UNI-COUPLE 20 TO 30 MILLIVOLTS THERMOCOUPLES 24" (60CM)
The Robertshaw 1970 Series Thermocouple Uni-Couple® design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermocouple's rolled threads for proper positioning in every application.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-048 1980 SNAP-FIT THERMOCOUPLE 48" (120CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-030 1980 SNAP-FIT THERMOCOUPLE 30"
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1970-036 UNI-COUPLE 20 TO 30 MILLIVOLTS THERMOCOUPLES 36" (91CM)
The Robertshaw 1970 Series Thermocouple Uni-Couple® design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermocouple's rolled threads for proper positioning in every application.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-018 1980 SNAP-FIT THERMOCOUPLE 18" (45CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1950-001 1950 & 1951 THERMOPILES 36" (91CM)
The Robertshaw® 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output.

Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors. The 1950 Series Thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 Series Thermopiles, also known as CP-2 (250 to 750 millivolts), are coaxial connectors. The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices. It includes PG9 Pilot Adaptor.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-036 1980 SNAP-FIT THERMOCOUPLE 36" (91CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
1980-024 1980 SNAP-FIT THERMOCOUPLE 24" (60CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
Login to Access Pricing 0.0 CAD
780-502 DS 845, 24V DIRECT SPARK IGNITION
The Robertshaw® 780 Series Direct Spark Controls are applicable to commercial cooking equipment, gas fired heating, and water heating systems of many types. The system acts on a demand for heat by a switch or thermostat to open the gas valve. At the same time, the 780 series ignition control supplies a spark to the electrode which ignites the gas. After the gas is lit, an electronic circuit proves the presence of flame using flame rectification. When the thermostat is satisfied, the gas valve will be closed to shut off the main burner gas.

Features and Benefits
Replaces one rod and/or two rod systems
Easy-to-install with complete in-depth installation instructions
Reduces truck stock inventory, saving space and money
Login to Access Pricing 0.0 CAD
780-001 GAS IGNITION CONTROL - NONLOCKOUT
The Robertshaw® 780 Series Pilot Controls Uni-Kits® feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application. The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner. The Robertshaw lockout version kits include the capability to shut off all gas to the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides three tries for ignition. Each ignition period is 90 seconds followed by a six minute time delay between ignition attempts. If the pilot flame is not sensed after three tries, the unit goes into lockout and must be reset at the thermostat.

Features and Benefits

Replaces one rod and/or two rod systems
Reduces truck stock inventory, saving space and money
Includes vent damper adapter assembly
Easy-to-install with complete in-depth installation instructions
Pilot and main valves draw 1 Amp at 0.5 power factor
Combined load at 1.5 Amps at 0.4 power factor
95% relative humidity noncondensing at 104°F
Login to Access Pricing 0.0 CAD

AS WE WORK HARD ON OPENING OUR IN-PERSON HVAC STORE, 

WE’RE EXCITED TO ANNOUNCE OUR ONLINE SHOP IS LIVE!   

For now, we’ve carefully selected HVAC products to get you started. 

Our inventory will expand, so stay tuned for more options as we grow! Thank you for being part of our journey. 🚀

Shop Grid Product
No results found for ''. Showing results for ''.
Drag building blocks here to customize the header for "" category.

No product defined

No product defined in this category.

No results

No results for "" in category "".

Click 'New' in the top-right corner to create your first product.