ZF13K4-ETF-5931 COPELAND SCROLL DIGITAL REFRIGERATION COMPRESSOR
The newest compressor technology, more efficient, more fault tolerant, more adaptable. Some applications may require liquid injection.

Suitable for applications:
-40°F to +30°F -R404A, R507, R134a, R448A
-40°F to +45°F -R22
Listed Capacity at -25°F and 90°F ambient
Rated Load Amps: R404A Applications/R22 Applications
Note single phase units not rated R22. RLA for R404A only
Run Capacitor required for operation, not provided
RL connections require valve or adapter
These compressors can be used with a variety of refrigerants at varying conditions. Observe the refrigerant and temperature guidelines and contact your United branch for applications outside the specified boundaries.
114N6744 OPTYMA™ LOW 7.5HP 3PH
114N6744 OPTYMA™ LOW 7.5HP 3PH
Compressor power supply [V]: 230/3/60

R404A/R507 Capacity range: 44230 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 10250W, AWEF 3.47
M6KP-0102-CAV-072 1HP 208/230-1
Copelaweld Hermetic Air-Cooled Condensing Units
Condensing Unit, 1hp 208/230-1 Herm 3/8“S / 1/2“S Air

Receiver
Fan guard
BX Conduit
All 3-phase models have single phase fan motors
R-22 Models have accumulator (2 hp up)
Electrical:
CAA, CFA, IAA, SAA: 115-1-60
CAV, CFV, IAV: 208/230-1-60
* F - Flare, S - Sweat, RF - Rotolock flare, RS - Rotolock sweat

M Series K Chassis Hermetic Reciprocating Air-Cooled Condensing Unit

Air Cooled steel - 24" x 16.1"
Copelaweld M6KP-0102 Hermetic Air-Cooled Condensing Unit

Medium Temperature Conditions @ 90° - Evap Temps 10 / 15 / 20 / 25
R-404A: 6,910 / 7,620 / 8,370 / 9,150 BTUH
R-448A: 6,330 / 7,120 / 8,000 / 8,960 BTUH
R-449A: 6,340 / 7,130 / 8,010 / 8,970 BTUH
Low Temperature Conditions @ 90° - Evap Temps -10 / -20 / -30
R-404A: 4,420 / 3,350 / -- BTUH
R-448A: 3,790 / -- / -- BTUH
R-448A: 3,800 / -- / -- BTUH
114N3587 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 5HP 1PH
114N3587 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 5HP 1PH
Compressor power supply [V]: 230/1/60
OP-HRXM0500UWK000N

R448A/R449A Capacity range: 41710 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 5406W, AWEF 9.06

R404A/R507 Capacity range: 45690 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 5430W, AWEF 9.64
114N3597 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 8HP 3PH
114N3597 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 8HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0600UWL000Q

R448A/R449A Capacity range: 27310 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 6222W, AWEF 3.39

R404A/R507 Capacity range: 33350 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 6360W, AWEF 3.76
114N3596 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 6HP 3PH
114N3596 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 6HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0600UWL000Q

R448A/R449A Capacity range: 20630 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 5385W, AWEF 3.26

R404A/R507 Capacity range: 25730 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 5513W, AWEF 3.53
114N3595 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 5HP 3PH
114N3595 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 5HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0500UWL000Q

R448A/R449A Capacity range: 18620 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 4297W, AWEF 3.48

R404A/R507 Capacity range: 22070 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 4462W, AWEF 3.77
114N3594 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 4HP 3PH
114N3594 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 4HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0400UWL000Q

R448A/R449A Capacity range: 15220 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 3563W, AWEF 3.41

R404A/R507 Capacity range: 18280 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 3672W, AWEF 3.81
114N3593 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 10HP 3PH
114N3593 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 10HP 3PH
Compressor power supply [V]: 230/3/60
HRXM1000UWK000Q

R448A/R449A Capacity range: 82280 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 9991W, AWEF 9.88

R404A/R507 Capacity range: 90760 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 10580W, AWEF 10.3
114N3592 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7.5HP 3PH
114N3592 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7.5HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0750UWK000Q

R448A/R449A Capacity range: 66910 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 7665W, AWEF 10.28

R404A/R507 Capacity range: 72410 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 8089W, AWEF 10.66
114N3591 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7HP 3PH
114N3591 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0700UWK000Q

R448A/R449A Capacity range: 55260 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6907W, AWEF 9.83

R404A/R507 Capacity range: 58470 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6912W, AWEF 10.45
114N3589 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 6HP 3PH
114N3589 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 6HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0600UWK000Q

R448A/R449A Capacity range: 50610 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6504W, AWEF 9.64

R404A/R507 Capacity range: 54180 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6264W, AWEF 10.57
114N3588 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 5HP 3PH
114N3588 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 5HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0500UWK000Q

R448A/R449A Capacity range: 41710 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 5406W, AWEF 9.06

R404A/R507 Capacity range: 45690 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 5430W, AWEF 9.64
114N3586 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 4HP 3PH
114N3586 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 4HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0400UWK000Q

R448A/R449A Capacity range: 34040 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 4455W, AWEF 9.40

R404A/R507 Capacity range: 36450 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 4596W, AWEF 9.62
114N3585 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 4HP 1PH
114N3585 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 4HP 1PH
Compressor power supply [V]: 230/1/60
OP-HNXM0400UWK000N

R448A/R449A Capacity range: 34040 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 4455W, AWEF 9.40

R404A/R507 Capacity range: 36450 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 4596W, AWEF 9.62
114N3584 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 3.5HP 3PH
114N3584 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 3.5HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0350UWK000Q

R448A/R449A Capacity range: 28890 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3826W, AWEF 9.22

R404A/R507 Capacity range: 31910 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3829W, AWEF 10.33


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.