780-001 GAS IGNITION CONTROL - NONLOCKOUT
The Robertshaw® 780 Series Pilot Controls Uni-Kits® feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application. The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner. The Robertshaw lockout version kits include the capability to shut off all gas to the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides three tries for ignition. Each ignition period is 90 seconds followed by a six minute time delay between ignition attempts. If the pilot flame is not sensed after three tries, the unit goes into lockout and must be reset at the thermostat.

Features and Benefits

Replaces one rod and/or two rod systems
Reduces truck stock inventory, saving space and money
Includes vent damper adapter assembly
Easy-to-install with complete in-depth installation instructions
Pilot and main valves draw 1 Amp at 0.5 power factor
Combined load at 1.5 Amps at 0.4 power factor
95% relative humidity noncondensing at 104°F
BX75QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
SILVALOY 452 FLUX COATED BLUE ROD .062 X 18" X 8 STICK TUBE
SILVALOY 452 FLUX COATED (Blue)
Product Overview

Silvaloy 452 Flux Coated is a flux coated Silvaloy brazing rod. In addition to bare and cored high silver brazing alloys, we also offer rods that are coated with our general purpose Handy Flux.
Improved joint strength due to less flux inclusions
Minimizes post-braze cleaning
Reduces brazing cycle times
Made in the USA
Industry Applications:
Brass band instuments, brass lamps, aircraft engine coolers
034L0023 KVP 12 EVAPORATOR PRES. REG. M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0026 KVP 28 EVAPORATOR PRES. REG. M/7
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0143 KVC 12 HOT GAS BYPASS REG M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
014L0183 SGP 12S N SIGHT GLASS M/28
SGP - Sight Glasses
Danfoss sight glasses with hard crystal view ports are designed to accurately indicate the presence of moisture in refrigeration and airconditioning
systems. When system moisture content rises above permissible levels, the “dry/green” indicator will change to yellow indicating
a “wet” system. The indication of dangerous moisture levels is essential in helping prevent the formation of harmful acids which are detrimental
to the system. The SGP sight glass is simply the best-made sight glass available today.
032L1104 EVR 32 VALVE ODF-ODF 1 5/8IN SINGLEP.
EVR Version 2 - Solenoid Valves
EVR Version 2 solenoid valves are direct or servo-operated solenoid valves for liquid, suction, and hot gas lines. They are suitable for all
refrigeration, freezing, and air conditioning applications and are compatible with fuorinated refrigerants. The valves can be delivered as
normally open or closed as well as with or without manual operation.
RCO220 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 230V, 7.5A

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run
ULTRA FLUX 7 OZ BRUSH CAP
ULTRA FLUX
Product Overview

Ultra Flux is a low spattering water based active flux which is used in open air brazing for both ferrous and non-ferrous metals to promote oxide removal.
Premium grade
Low spattering
Good part adhesion
Made in USA
Industry Applications:
Low temperature silver braze alloys (1100F-1600F)
023Z1015 BURN-OUT FILTER DRIER DAS 307SVV M/8
DCL/DCB/DAS/DCR - Filter Driers
Danfoss lter driers function as simple drop-in replacements for most driers sold in the aftermarket or installed on equipment by
manufacturers. All Danfoss lter driers are constructed with a solid core design to maximize moisture removal while minimizing pressure
drop. These driers use a mixture of molecular sieve and activated alumina to both adsorb system moisture and capture acid and prevent
solid contaminants from entering the system. The Danfoss 1.5 cubic inch hermetic lter drier can be used in hydrocarbon systems to provide
exceptional protection while minimizing charge requirements.
B78 HI POWER V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
BX57QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
VIPER FOAM GUN SPRAYER
FOAM SPRAYER
Just fill the container with full strength coil cleaning concentrate. No mixing or pre-dilution. Simply connect to any garden hose. Dial in a dilution ratio, aim, and fire.
Foam cleaning is the most efficient method of coil cleaning. Typically, one gallon of coil cleaner will produce enough foam to clean five, 5 ton condenser coils.
For best results, we recommend using our high foaming concentrates, Viper Heavy Duty or Viper Brite.

5 Dilution Ratios
No Mixing Required
Saves Time and Money
VCCA-20ULS, 115V LOW-PROFILE CONDENSATE PUMP
The VCCA-20 Series Condensate Pump is designed for the automatic collection and removal of condensate from air conditioning, refrigeration and dehumidification equipment when gravity drainage is not possible or practical. Also, suitable for high efficiency oil and gas-fired condensing furnace and condensing boiler equipment.
032L1240 EVR 20 VALVE ODF-ODF 7/8IN MULTI 6
EVR Version 2 - Solenoid Valves
EVR Version 2 solenoid valves are direct or servo-operated solenoid valves for liquid, suction, and hot gas lines. They are suitable for all
refrigeration, freezing, and air conditioning applications and are compatible with fuorinated refrigerants. The valves can be delivered as
normally open or closed as well as with or without manual operation.
RCO410 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 115V, 6.8A

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run
034N0083 CPCE 15 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
TREMSIL® 200 - BLACK SILICONE SEALANT
Single-Component, Acetoxy Silicone Sealant
Tremsil® 200 is a single-component, acetoxy silicone sealant. Tremsil 200 cures to a flexible rubber when exposed to moisture present in the air.

Basic Uses
Tremsil 200 produces a weathertight seal to glass, metal, porcelain, ceramic and most painted surfaces.
Tremsil 200 sealant is suitable for use in kitchens, bathrooms and spas.
RS9423T MULTI-STAGE 4 HEAT / 2 COOL PROGRAMMABLE TOUCHSCREEN HUMIDITY CONTROL THERMOSTAT
Pro-Series Programmable Touchscreen Wall Thermostat
Contractors can offer owners easy, yet powerful and reliable multi-stage temperature control in a simple, modern design with the Robertshaw RS9423T Programmable Touchscreen Wall Thermostat. The RS9423T is a Multi-Stage thermostat with 4 Heat / 2 Cool, Dual Fuel Compatibility and IAQ features.

• Compatible with Wireless Outdoor Temperature Sensor (RS9055OUT) for Duel Fuel balance point applications
• Large terminal blocks for easy installation
• Universal sub-base
• Quick-access menu button
• Contractor/technician setup menu
• Easy-to-understand programming menus
• Intuitive wake, leave, return, sleep programming icons
• 24V AC Powered OR Battery Operation (Included)
• 6 Year Limited Warranty
• Factory pre-set energy efficiency program
• Large, easy-to-read 8.8-square-inch blue backlit touchscreen display
• Easy access front load battery compartment
• Adjustable temperature differential (swing) for energy optimization and maximum system life
• Adjustable room temperature calibration
• Adjustable setpoint limits
• Five-minute selectable on/off compressor delay protection for short-cycling prevention
• Filter change reminder (selectable on/off)
• Keypad lockout
710-502 MILLIVOLT LOW CAPACITY GAS VALVE
710 Series - Low Capacity
The Robertshaw® 710 Series Low Capacity Gas Valves feature an extremely compact control designed for low capacity and limited space applications. Features include three-position outlets, multi-positional capability and component replaceability.

Features and Benefits
Low capacity with 3-13/16”H x 4-21/32”L x 1-29/32” W dimensions
Gas cock dial marking Off - Pilot - On
Ambient temperature of -40°F to 175°F
Pilot outlet 1/4” tubing
Maximum inlet pressure 14” WC (0.5 PSI)
Standard NEMA terminals
Inlet filtered screen
Various gas types: natural, manufactured, mixed, LP, and LP/air mixtures
Multiple actuators available
RoHS compliant
034N0084 CPCE 22 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
BX60QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
020B1011 NRV 10S CHECK VALVE SW M/25X4
NRV V2 - Check Valves
NRV V2 one-piece check valves are used in liquid suction and hot gas lines in refrigeration and air conditioning applications. NRV valves ensure
the correct low direction and prevent back-condensation from a warm part of the system to the cold evaporator. The hermetic design of
solder version meets environmental demands for today and the future. The built-in damping piston makes the valves suitable for installation in
lines where pulsation can occur, e.g., in a compressor discharge line.
034L0043 KVL 12 CRANKCASE PRES. REG. M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
023Z1436 BIFLOW FILTER DRIER DCB 164S M/12
DCL/DCB/DAS/DCR - Filter Driers
Danfoss lter driers function as simple drop-in replacements for most driers sold in the aftermarket or installed on equipment by
manufacturers. All Danfoss lter driers are constructed with a solid core design to maximize moisture removal while minimizing pressure
drop. These driers use a mixture of molecular sieve and activated alumina to both adsorb system moisture and capture acid and prevent
solid contaminants from entering the system. The Danfoss 1.5 cubic inch hermetic lter drier can be used in hydrocarbon systems to provide
exceptional protection while minimizing charge requirements.
NYLOG BLUE SEALANT 30ML TUBE (2 PACK)
GASKET & THREAD SEALANT
Nylog Blue is an elastic fluid made from synthetic refrigeration grade compressor oil. Nylog Blue is fully miscible and compatible with all system refrigerants and oils. Gaskets coated with Nylog will never dry or become heat fixed to the surface. Threaded connections coated with Nylog will block high pressure leaks by forming a hydraulic seal. Nylog can be used an assembly lube when installing shaft seals, o-rings, schraeder valves, ball valves, or other internal system components.
VIPER HEAT BLOCKING GEL QUART
HEAT BLOCKING GEL
Viper Heat Blocking Gel is used to prevent fire or heat damage when using an open flame around wood, drywall, fabric and other components. It can also be used as a heat dissipating gel when protecting sensitive components in low temperature soldering applications. For high temperature brazing, soldering or welding we recommend our Viper Heat Blocking Putty.

Prevents Fires
Protects Sensitive Components
Wipes off easily
Non-Toxic and No Odors

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.