Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
VINYL TUBING T-20/25 X 20FT
T-20/25 Tubing, 3/8" x 20FT
114N3589 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 6HP 3PH
114N3589 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 6HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0600UWK000Q

R448A/R449A Capacity range: 50610 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6504W, AWEF 9.64

R404A/R507 Capacity range: 54180 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6264W, AWEF 10.57
2374-495 ADJUSTABLE AIR SENSING SWITCH 0.25" TO 1.0" WC
The Robertshaw® 2374 Series Adjustable Air Sensing Switches are designed to replace a wide variety of air sensing switches found in residential and light commercial applications including furnaces, electronic air cleaners and humidifiers. Two models are currently available with adjustable ranges. Both models are provided with an SPDT switch that can be actuated by positive or negative pressure or by pressure differential. Highly accurate, these switches are practically insensitive to temperature change with an operating temperature range of -40°F to 190°F (-40°C to 88°C). Each switch includes mounting hardware and an adjustment tool for easy installation and calibration.

Features and Benefits
Field adjustable control set point
Air sample line connectors will accept 1/8”, 1/4” or 3/8” tubing
Electrical connection is 1/4” spade
Vertical operating mounting position for diaphragm
UL File Number MH6213, CSA File Number LR18754
034L0100 KVR 35 CONDENSING PRES. REG. M/7
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
AX40QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
BX71QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
014L0181 SGP 6S N SIGHT GLASS M/25X4
SGP - Sight Glasses
Danfoss sight glasses with hard crystal view ports are designed to accurately indicate the presence of moisture in refrigeration and airconditioning
systems. When system moisture content rises above permissible levels, the “dry/green” indicator will change to yellow indicating
a “wet” system. The indication of dangerous moisture levels is essential in helping prevent the formation of harmful acids which are detrimental
to the system. The SGP sight glass is simply the best-made sight glass available today.
BX38QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
BX56QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
AX28QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
BX55QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
018F4180 COIL GP DV - 110/240V JUNCTION BOX 7IN.
EVR Version 2 - Solenoid Valves
EVR Version 2 solenoid valves are direct or servo-operated solenoid valves for liquid, suction, and hot gas lines. They are suitable for all
refrigeration, freezing, and air conditioning applications and are compatible with fuorinated refrigerants. The valves can be delivered as
normally open or closed as well as with or without manual operation.
AX60QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
023Z8255 FILTER DRIER DCL 1.52/2.8MMS M/32
DCL with Schrader valve - Filter Driers
The Danfoss 1.5 hermetic lter driers include a Schrader valve, making servicing the system easy and convenient, and convertible outlet for
tting on capillary tube or ¼ inch system connection. Thanks to the solid core, Danfoss ELIMINATOR® lter driers oer exceptional drying
capacity to protect the system against harmful acids and moisture. The DCL 1.5 cubic inch lter drier with Shrader makes an excellent upgrade
in replacing loose bead driers due to superior drying and small internal volume.
114N3592 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7.5HP 3PH
114N3592 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7.5HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0750UWK000Q

R448A/R449A Capacity range: 66910 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 7665W, AWEF 10.28

R404A/R507 Capacity range: 72410 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 8089W, AWEF 10.66
2374-498 ADJUSTABLE AIR SENSING SWITCH 1.0" TO 4.0" WC
The Robertshaw® 2374 Series Adjustable Air Sensing Switches are designed to replace a wide variety of air sensing switches found in residential and light commercial applications including furnaces, electronic air cleaners and humidifiers. Two models are currently available with adjustable ranges. Both models are provided with an SPDT switch that can be actuated by positive or negative pressure or by pressure differential. Highly accurate, these switches are practically insensitive to temperature change with an operating temperature range of -40°F to 190°F (-40°C to 88°C). Each switch includes mounting hardware and an adjustment tool for easy installation and calibration.

Features and Benefits
Field adjustable control set point
Air sample line connectors will accept 1/8”, 1/4” or 3/8” tubing
Electrical connection is 1/4” spade
Vertical operating mounting position for diaphragm
UL File Number MH6213, CSA File Number LR18754
RCO220 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 230V, 7.5A

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run
034N0082 CPCE 12 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
BX67QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
CCH0005MBACZ 0.5HP MED 1PH
CU CC SCRL 0.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 7,660 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.