Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
A32 V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
SF3602 ACCESS FITTING 1/4", 3/16", 1/8" BUSHINGS - 6 EA
Line service valve ¼" copper tubing, 3/16" & ⅛" copper bushings, wrench cap & core

Features/Benefits

¼" Copper Tubing, 3/16" and ⅛" Copper Bushings
Made of CDA 360 brass
Wrench Cap and Core
P70MA-2C FOR AMMONIA; 20/100 PSIG LS 15 RANGE 100/425 PSIG HS
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
A23 HI POWER V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
O12-1594 DUAL PRESSURE CONTROL LOW PRESSURE 10" TO 100 PSI MANUAL RESET, HIGH PRESSURE 150 TO 450 PSI MANUAL RESET
The Ranco® Dual Pressure Controls combine the functions of a single high-pressure limit control and a single low-pressure control in one unit with a single pole, single throw (SPST) switch.

Features and Benefits

Convertible feature allows selection of manual or reset function when operating at high pressure (O12‑4833/O12-4834)
A wide range of high-pressure manual or automatic reset controls can be replaced (O12-4833 or O12‑4834)
A high-pressure limit is combined with suction pressure sensing to provide temperature control and/or pump down
High-limit adjustment screw
Low-pressure differential and range adjusting screws
Selector screw for manual or automatic
Reset button
Low-pressure scale plate
High-impact plastic cover with center mount screw
High-pressure scale plate
Super Cap® capillary protection system
Color-coded for easy identification of pressure line
High-side capillary flare nut (silver)
Low-side capillary flare nut (brass)
TFXDMP DISCONNECT MOUNTING PLATE
A universal way to secure the disconnect to the unit, without blocking access to the electrical panel.

Features/Benefits

Designed to fit various layouts of single phase disconnects
Cross pattern mounting allows for universal installations
Hex nuts for easy installation with 5/16" nut driver
Eliminates potential damage to the unit during installation
Made of weather-resistant galvanized metal
Part of our SUPCO® TradeFox™ Technician-Invented product line
FAN BLADE 7" 18P CW
MaterialAluminum, Zinc coated steel ConstructionOne-piece; hubbed, hubless, or unit-bearing
BRO - RUBRS-112 CARTRIDGE BALL BEARING
Cartridge Bearing; 3/4" Bore; 2-17/32" Outside Diameter; 1" Cartridge Housing Width; Set Screw; Cartridge Unit Housing; Rubber; Ball Bearing; 1.38" Length Thru Bore; Not Relubricatable; SLRS-112 Insert; Single Lip Contact Seal; Non-Expansion
HVAC UV DYE CONCENTRATE 2 OZ SYRINGE IN CLAMSHELL
Finds leaks quickly & easily.
Solvent free, safe for all refrigerantion systems and equipment.
Compatible with all lubricants and refrigerants.
Anti-wear agents and friction modifiers enhance compressor and A/C system efficiency while reducing compressor wear.
Anti-oxidants protect system against formation of sludge & other deposits.
BRO - RUBRS-116 CARTRIDGE BALL BEARING
Cartridge Bearing; 1" Bore; 2-17/32" Outside Diameter; 1" Cartridge Housing Width; Set Screw; Cartridge Unit Housing; Rubber; Ball Bearing; 1.38" Length Thru Bore; Not Relubricatable; SLRS-116 Insert; Single Lip Contact Seal; Non-Expansion
10-6850 FLAME SENSOR TRANE DIRECT REPLACEMENT WITH A 90° BEND
680 Series
Enhance the performance and safety of your HVAC system with the Robertshaw® Trane Direct Replacement Flame Sensor with a 90° Bend.

Designed as an exact match for Trane's SEN01114.

Will fit over 500 Trane furnace series, AUC1D1, AUD1, AUD2, TDC1, TDD1, TDD2, TDH1, TDH2, TDH3, TDHM, TUD1, TUD2, TUE, TUH.
A55 HI POWER V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
TRADEFOX TFXJK FUSED MULTI JUMPER WITH SELECTOR SWITCHES
The Jumper King° allows you to quickly bypass any low voltage thermostat regardless of terminal style. This patent-pending all-in-one kit comes with everything you need to locate low-voltage shorts and eliminate compressor short cycling.

Features/Benefits

2-Spade Adapters, Jumper King° Thermostat Bypass Tool, Hard Carrying Case
6-Alligator Clips, 6-Magnetic Tips, 6-Jumper Leads, 6-Self Piercing Insulation Tips
For Use on low voltage circuits only (0-30VAC/VDC)
Four types of interchangeable tips: spade adapters, alligator clamps, magnetic tips and self-piercing insulation tips
Inovative selector switches to activate leads/circuits of your choosing at any time
No batteries required - powered by the low voltage in theA/C unit
Rugged unit has a rubberized boot, a magnet and fold-out hook for convenient mounting
Will never short out - contains a resettable popper fuse
Works on multiple stage units including heat pumps
A34 HI POWER V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
41-602 HOT SURFACE FURNACE MINI-IGNITOR
Made of durable, non-porous silicon nitride, Robertshaw® Mini Ignitors provide reliable ignition in a small footprint. They offer contractors easy handling, simple installation and dependable operation.

Dependable ignition in a small footprint
Constructed with unique non-porous, high-strength material
3 second heat-up time
Easy to handle and install
Trouble-free operation
A35 HI POWER V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
J10-809W DEHUMIDISTAT - WALL MOUNT
The J10 Series Humidistats and Dehumidistats are designed to regulate the relative humidity of confined spaces by cycling humidifying or dehumidifying equipment. Designed for central systems, the J10 controls are made from high impact plastic with a brushed finish dial plate. The J10's nylon sensing element provides long life and accurate humidity control. The J10-809W dehumidistat is designed to be wall mounted and can be wired in series or parallel with a 24 volt nonelectric thermostat.

Features and Benefits

Strong plastic frame with integral switch eliminates the need to ground the control
Improved woven nylon sensing element provides a faster response time
Greater stability in set points over dramatic changes in relative humidity
Improved differential allowing 5% relative humidity
032L0550 EVR 6-8 NC V2 SERVICE KIT MU10
Service kit (NC); diaphragm assembly, O-ring, (4) screws, armature assembly, rubber gasket, support ring, compression ring
A28 HI POWER V-BELT
The wrapped classical section Hi-Power™ V-belt has a long reputation for reliability on agricultural and industrial applications. The arched top of the Hi-Power belt provides superior strength to prevent "dishing" and distortion of the tensile section. The cords are properly aligned, each of them carrying its full share of the load.

Arched top, concave sidewalls and rounded corners provide uniform tensile loading and uniform pulley sidewall contact for excellent belt service life and reduced pulley wear.

Vulcanized Flex-bonded tensile cords provide superior resistance to tensile and flexing forces, fatigue and shock loads.

Flex-Weave™ oil and heat resistant cover protects the belt core from the toughest environments.

All sizes meet Gates V80™ system matching tolerances.

Meets ARPM/RMA IP-3-2 oil and heat resistant standards and IP-3-3 static conductivity requirements. REACH and RoHS 2 compliant.
060-5244 KPU6B PRESSURE SWITCH M/14
KPU - Pressure Switches
KPU pressure switches are designed to be contractor friendly and used in refrigeration and air-conditioning systems to protect the systems
from excessively low suction or high discharge pressure. They can also be applied to start and stop compressors and the fans of air-cooled
condensers. KPU pressure switches, in single and dual versions, cover a comprehensive range of applications and are designed for use with
Fluorinated and non-aggressive refrigerants. Most KPU pressure controls can be used with R-410a systems with only a few code numbers.
060-5233 KPU1 PRESSURE SWITCH M/10
KPU - Pressure Switches
KPU pressure switches are designed to be contractor friendly and used in refrigeration and air-conditioning systems to protect the systems
from excessively low suction or high discharge pressure. They can also be applied to start and stop compressors and the fans of air-cooled
condensers. KPU pressure switches, in single and dual versions, cover a comprehensive range of applications and are designed for use with
Fluorinated and non-aggressive refrigerants. Most KPU pressure controls can be used with R-410a systems with only a few code numbers.
060B200791 MP55 DIFF. PRESSURE SWITCH M/21
MP - Differential Pressure Switch / Lube Oil Protection Switch
MP 54 and MP 55 oil differential pressure switches are used to protect refrigeration compressors against low oil pressure. These switches are
compatible with HCFC and non-flammable HFC refrigerants.
060B200391 MP54 DIFF. PRESSURE SWITCH M/21
MP - Differential Pressure Switch / Lube Oil Protection Switch
MP 54 and MP 55 oil differential pressure switches are used to protect refrigeration compressors against low oil pressure. These switches are
compatible with HCFC and non-flammable HFC refrigerants.
060-5254 KPU16B PRESSURE SWITCH M/10
KPU - Pressure Switches
KPU pressure switches are designed to be contractor friendly and used in refrigeration and air-conditioning systems to protect the systems
from excessively low suction or high discharge pressure. They can also be applied to start and stop compressors and the fans of air-cooled
condensers. KPU pressure switches, in single and dual versions, cover a comprehensive range of applications and are designed for use with
Fluorinated and non-aggressive refrigerants. Most KPU pressure controls can be used with R-410a systems with only a few code numbers.
RCO810 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 115V, 10A

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run
RCO410 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 115V, 6.8A

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run
RCO210 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 115V, 40A

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run
RCO420 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD AND START, RLY, 230V

Prevents low voltage starting problems
Replaces relay, overload and provides a boost for hard start and unbalanced systems
Wire designations - white/start, black/common, red/run


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.