Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.



Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
CEC0095AS7AMB - 9,100 BTU/H LVC 2F
UC C CM AIR 2F 115 1PH M STD S 1
Evap. Temp : 25 °F
Voltage : 115/1/60
Room Temp :
Application Capacity* : 9,100 BTU/H
Refrigerant Type : R448A
Cooler AWEF > 32 : 9
Freezer AWEF <= 32 : N/A
CEC0130AS7AMA - 13,000 BTU/H LVC 3F
UC C CM AIR 2F 115 1PH M STD S 1
Evap. Temp : 25 °F
Voltage : 115/1/60
Room Temp :
Application Capacity* : 13,000 BTU/H
Refrigerant Type : R448A
Cooler AWEF > 32 : 9
Freezer AWEF <= 32 : N/A
CEC0250AS7AMA - 24,700 BTU/H LVC 4F
UC C CM AIR 4F 115 1PH M STD S 1
Evap. Temp : 25 °F
Voltage : 115/1/60
Room Temp :
Application Capacity* : 24,700 BTU/H
Refrigerant Type : R448A
Cooler AWEF > 32 : 9
Freezer AWEF <= 32 : N/A
CCH0005MBACZ 0.5HP MED 1PH
CU CC SCRL 0.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 7,660 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0008MBACZ 0.8HP MED 1PH
CU CC SCRL 0.8HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 8,980 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0025LBACZ 2.5HP LOW 1PH
CU CC SCRL 2.5HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/1/60
Application Capacity* : 11,970 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.15
CCH0010MBACZ 1.0HP MED 1PH
CU CC SCRL 1.0HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 12,200 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0015MBACZ 1.5HP MED 1PH
CU CC SCRL 1.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 17,540 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0020MBACZ 2.0HP MED 1PH
CU CC SCRL 2.0HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 16,410 BTU/H
Refrigerant Type : R448A
AWEF Value : 7.6"
CCH0025MBACZ 2.5HP MED 1PH
CU CC SCRL 2.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 22,860 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0030MBACZ 3.0HP MED 1PH
CU CC SCRL 2.0HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 31,930 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0055MCACZ 5.5HP MED 3PH
CU CC SCRL 5.5HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25.0 °F
Voltage : 208-230/3/60
Application Capacity* : 42,200 BTU/H
Refrigerant Type : R448A
AWEF Value : 7.6"
SFC75120 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC300400 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC275350 FAN CYCLE PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45L female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Will not replace solenoids with internal metering orifices
SFC210275 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC200365 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC200240 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC170250 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC150225 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC125265 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SFC110170 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SF9644 COUPLER, 1/4" FEMALE FLARE X (3) 1/4" MALE FLARES
Connector with two, ¼" male flares, one with core and cap in a 'U' shape. At the side is a ¼" female flare with depressor tip, and opposite that is an additional ¼" male flare.

Features/Benefits

¼" female flare with depressor tip on side and opposite is an additional ¼" male flare
Two ¼" male flares, one with core and cap, in a U shape
SF9614 TEE BRASS, 1/4" MALE FLARE X 1/4" MPT X 1/4" MALE FLARE ON BRANCH - 2 EA
SF9600 Series ¼" flare forged access tees with forged brass tee and ¼" flares are threaded for valve cores

Features/Benefits

¼" male flare x ¼" MPT x ¼" male flare access on branch
One cap
One valve core
SF9603 TEE BRASS, 1/4" MALE FLARE X 1/4" MALE FLARE X FEMALE FLARE ON BRANCH
Tee connector with 1/4" male flare access and valve core X 1/4" male flare access X 1/4" female flare with depressor tip.

Features/Benefits

¼" male flare with valve core and cap x ¼" male flare x ¼" female flare nut with depressor tip on the branch
All brass connector tee
SF9602 TEE COPPER, 1/4" MALE FLARE X 1/4" MALE FLARE X FEMALE FLARE ON BRANCH - 2 EA
Tee connector with depressor tip and one valve core along the straight length, and an additional valve core at a 90° angle.

Features/Benefits

¼" male flare with valve core x ¼" male flare x ¼" female flare nut with depressor tip on the branch
SF9601 TEE COPPER, 1/4" MALE FLARE X 1/4" FEMALE FLARE X MALE FLARE ON BRANCH - 2 EA
Tee connector with depressor tip and one valve core along the straight length, and an additional valve core at a 90° angle.

Features/Benefits

1/4" nut on depressor tip
Two 1/4" male flare ends with valve core
SF8725 ACCESS BODY, 1/4" MALE FLARE, 1/4" FEMALE FLARE - 2 EA
The valve body is stationary. When threads of the existing system fittings are stripped, and a new core will not go in, you can use SF8725.

Features/Benefits

Has a core and no depressor tip
Use when threads of existing system fittings are stripped and a new core wont go in
Valve body is stationary


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".