  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
014L0173 SGP 12 N SIGHT GLASS M/24X3
SGP - Sight Glasses
Danfoss sight glasses with hard crystal view ports are designed to accurately indicate the presence of moisture in refrigeration and airconditioning
systems. When system moisture content rises above permissible levels, the “dry/green” indicator will change to yellow indicating
a “wet” system. The indication of dangerous moisture levels is essential in helping prevent the formation of harmful acids which are detrimental
to the system. The SGP sight glass is simply the best-made sight glass available today.
014L0183 SGP 12S N SIGHT GLASS M/28
SGP - Sight Glasses
Danfoss sight glasses with hard crystal view ports are designed to accurately indicate the presence of moisture in refrigeration and airconditioning
systems. When system moisture content rises above permissible levels, the “dry/green” indicator will change to yellow indicating
a “wet” system. The indication of dangerous moisture levels is essential in helping prevent the formation of harmful acids which are detrimental
to the system. The SGP sight glass is simply the best-made sight glass available today.
014L0182 SGP 10S N SIGHT GLASS M/25X4
SGP - Sight Glasses
Danfoss sight glasses with hard crystal view ports are designed to accurately indicate the presence of moisture in refrigeration and airconditioning
systems. When system moisture content rises above permissible levels, the “dry/green” indicator will change to yellow indicating
a “wet” system. The indication of dangerous moisture levels is essential in helping prevent the formation of harmful acids which are detrimental
to the system. The SGP sight glass is simply the best-made sight glass available today.
SIL-FOS 5 ROD .0940 DIA X 24" Per Stick
Sil-Fos 5 is a silver-copper-phosphorus alloy for copper-copper brazing but can also be used to join brass with an appropriate flux (e.g. Handy Flux, Ultra Flux). It is a more cost effective Ag-Cu-P alloy, though it does not penetrate deep joints easily.
Joins CU to CU (phosphorus serves as flux)
Joins CU to Brass (flux is recommended)
Lower cost alternative to higher silver content Ag-Cu-P alloys
Medium flow
Made in USA
Industry Applications:
HVAC/R refrigerant systems, air conditioning coils, evaporator coils

SA Item ID: 92030012
Mfg Part Number: 33136


LucasMilhaupt® Sil-Fos® 5 31894 Brazing Rod, 0.94 in Dia x 20 in L, 24 Rod Plastic Tube, 30000 to 40000 psi Tensile
LucasMilhaupt® Sil-Fos® 5 Brazing Rod, 0.94 in Dia, 20 in Length, Plastic Tube, 30000 to 40000 psi Tensile, Chemical Composition: Silver, Copper, Phosphorus, 1325 to 1500 deg F Brazing
032F0181 SPARE PART KIT EVR(H)2-3 MU10/120
Service kit (NC); O-ring, (4) screws, armature assembly, rubber gasket, compression spring
S903758 IGNITER KIT
Supco® igniters offer an efficient , stronger, reliable hot surface Silicon Carbide design.

Features/Benefits

18 gauge copper high temperature fiberglass insulated lead wires
Exact replacement hot surface igniters
Faster time to temperature response
Lower power consumption
Stronger more durable design
Superior gas lighting ability
ZF13K4-ETF-5931 COPELAND SCROLL DIGITAL REFRIGERATION COMPRESSOR
The newest compressor technology, more efficient, more fault tolerant, more adaptable. Some applications may require liquid injection.

Suitable for applications:
-40°F to +30°F -R404A, R507, R134a, R448A
-40°F to +45°F -R22
Listed Capacity at -25°F and 90°F ambient
Rated Load Amps: R404A Applications/R22 Applications
Note single phase units not rated R22. RLA for R404A only
Run Capacitor required for operation, not provided
RL connections require valve or adapter
These compressors can be used with a variety of refrigerants at varying conditions. Observe the refrigerant and temperature guidelines and contact your United branch for applications outside the specified boundaries.
ETC-212000-000 ELECTRONIC TEMPERATURE CONTROL - TWO STAGE - 24V AC
The Ranco® ETC Series Electronic Temperature Control offers a full-featured electronic replacement for electrical-mechanical temperature controls used in many commercial refrigeration applications. With its wide temperature range, one and two stage capability, selectable heating/cooling modes and multi-voltage input, the ETC is designed to provide application flexibility. Models available include 120/208/240V AC and 24V AC.

Features and Benefits

Anti-short cycle compressor delay for cooling applications
Wide temperature range (-30°F to 220°F) (-34.4°C to 104.4°C)
Wide differential adjustment (1°F to 30°F) (-17°C to -1°C)
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps @ 120V AC and 8 Amps @ 208/240V AC) single stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings
8 foot lead with sensor is extendable up to 400 feet using 18 or 22-gauge thermostat wire
Easy 4-step set-up
Heavy-duty relay is 1 HP rated
Selectable °F or °C heating/cooling modes
Single and two stage models
NEMA 1 case and cover
NEMA 4X models available
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
ETC-211000-000 ELECTRONIC TEMPERATURE CONTROL - TWO STAGE - 120/208/240V AC
The Ranco® ETC Series Electronic Temperature Control offers a full-featured electronic replacement for electrical-mechanical temperature controls used in many commercial refrigeration applications. With its wide temperature range, one and two stage capability, selectable heating/cooling modes and multi-voltage input, the ETC is designed to provide application flexibility. Models available include 120/208/240V AC and 24V AC.

Features and Benefits

Anti-short cycle compressor delay for cooling applications
Wide temperature range (-30°F to 220°F) (-34.4°C to 104.4°C)
Wide differential adjustment (1°F to 30°F) (-17°C to -1°C)
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps @ 120V AC and 8 Amps @ 208/240V AC) single stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings
8 foot lead with sensor is extendable up to 400 feet using 18 or 22-gauge thermostat wire
Easy 4-step set-up
Heavy-duty relay is 1 HP rated
Selectable °F or °C heating/cooling modes
Single and two stage models
NEMA 1 case and cover
NEMA 4X models available
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
712-017 INTERMITTENT PILOT IGNITION SYSTEM KIT
The Robertshaw® 712 Series Intermittent Pilot Ignition System Kit features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 pilot ignition systems are available with one of four different gas valve types to fit a wide range of furnace applications. Caution: Do not use on LP gas applications.

Features and Benefits

Quick and easy installation
Complete in-depth instructions and trouble shooting information
Used on natural gas systems only
VETO PRO PAC - TECH MCT
• 44 Interior & exterior
pockets of varying sizes
• Outside mounted stainless tape clip
• Electric tape strap
• YKK ® Locking Zippers
• Holds over 50 hand tools
• Waterproof base, 3mm polypropylene
• Extra wide padded
shoulder strap
• Over-molded ergonomic grip
• Light gray interior for
improved visibility
042H0172 SPARE PART KIT
Piston service kit (NC); (5) O-rings, Al. gasket, piston assembly, insert block, piston ring, compression spring, refrigeration gasket
VETO PRO PAC - MP1X BLACKOUT
• 9 Vertical pockets
• 2 Through pockets for long shanked tools
• Back Pocket Stuffer™
• Electrical tape strap
• 2 D-rings
• Wire-formed & nylon plastic belt clip
• Stainless tape clip
• Leather & synthetic fiber construction
• 5-year limited warranty
VETO PRO PAC - TP-XXL
• 46 available pockets
• V-SWAP™ removable tool pocket panel system
• Includes rear tablet pocket & 2 padded meter pockets
• “Hang-up” hook - accessible while open and closed
• Over-molded rubber grip
• Padded shoulder strap
• YKK® zippers
• Waterproof Polypropylene plastic base
• Tablet pocket dimensions: 11"H x 9"W x 1"D
• 5 year Limited Warranty
009G7012 GBC REPAIR KIT 6-22S WRENCH M/116
Ball valve service kit GBC 6, 10, 12, 16, 18, 22
700-506 MILLIVOLT DIAPHRAGM/SOLENOID GAS VALVE
700 Series - Millivolt The Robertshaw® 700 Series Millivolt Gas Valves are wall thermostat actuated combination controls which provide installation flexibility from furnaces to swimming pool applications. The complete line of 700-500 millivolt gas valves offers a wide range of replacements from small capacity 3/8” pipe to high capacity 1” pipe up to 720,000 BTU usage.

Features and Benefits
Gas cock dial marking Off - Pilot - On
Pilot outlet 1/4” tubing
Ambient temperature of -40°F to 175°F
Terminal type combination screw/spade
Maximum inlet pressure 14” WC (0.5 PSI)
Standard NEMA terminals
Inlet filtered screen
Various gas types: natural, manufactured, mixed, LP, and LP/air mixtures
RoHS compliant
8145-20M MECHANISM ONLY 208/240V AC TEMPERATURE OR PRESSURE TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
032L0548 EVR 4-8 NC V2 SEAL KIT MU10
Seal kit (NC/NO); O-ring for armature tube, rubber gasket, support ring

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.