Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
720-079 INTERMITTENT PILOT, DIRECT SPARK AND HOT SURFACE GAS VALVE
The Robertshaw® 720 Series Lever Actuated Gas Valves are designed for intermittent pilot ignition applications. This series incorporates a manual valve, pilot valve, dual automatic valves (2), and a main gas pressure regulator. Uni-Kit® models are factory set at 3.5” WC for natural gas, but can be converted to LP by installing the regulator conversion kit included. The 720 Series is designed for many residential applications such as central heating units, space heaters, wall heaters, boilers, and mobile home furnaces. This valve has a compact swing radius of only 3-9/16” to enable it to fit a wide range of OEM replacement applications.

Features and Benefits
Pilot outlet 1/4” tubing
1/4” quick connect terminal type
Ambient temperature of -40°F to 175°F
Maximum inlet pressure 14” WC (0.5 PSI)
Standard NEMA terminals
Rated as NEC Class 2
Inlet filtered screen
Various gas types: natural, manufactured, mixed, LP, and LP/air mixtures
RoHS compliant
VF3 RANCO UNIVERSAL REFRIGERATOR FREEZER TEMPERATURE CONTROL THERMOSTAT KIT
The Ranco® Varifix International Cold Controls are designed for fast and easy service replacements. They are available for both refrigerator and freezer applications.

Features and Benefits

Trusted brand
Capillary is crimped and sealed for maximum reliability
High level of performance
Complete kit includes all necessary hardware
VCCA-20ULS, 115V LOW-PROFILE CONDENSATE PUMP
The VCCA-20 Series Condensate Pump is designed for the automatic collection and removal of condensate from air conditioning, refrigeration and dehumidification equipment when gravity drainage is not possible or practical. Also, suitable for high efficiency oil and gas-fired condensing furnace and condensing boiler equipment.
032F0185 SPARE PART KIT EVR 10
Service kit (NC); diaphragm assembly, O-ring, (4) screws, armature assembly, rubber gasket, compression spring
TBS08 TECH-SET™ 1/2" SPRING TUBE BENDER
This 1/2in spring-type tube bender works for soft copper and aluminum. The end bell design aids in quick tubing removal.
700-506 MILLIVOLT DIAPHRAGM/SOLENOID GAS VALVE
700 Series - Millivolt The Robertshaw® 700 Series Millivolt Gas Valves are wall thermostat actuated combination controls which provide installation flexibility from furnaces to swimming pool applications. The complete line of 700-500 millivolt gas valves offers a wide range of replacements from small capacity 3/8” pipe to high capacity 1” pipe up to 720,000 BTU usage.

Features and Benefits
Gas cock dial marking Off - Pilot - On
Pilot outlet 1/4” tubing
Ambient temperature of -40°F to 175°F
Terminal type combination screw/spade
Maximum inlet pressure 14” WC (0.5 PSI)
Standard NEMA terminals
Inlet filtered screen
Various gas types: natural, manufactured, mixed, LP, and LP/air mixtures
RoHS compliant
VCCA-20ULS, 230V LOW-PROFILE CONDENSATE PUMP
VCCA-20ULS Series Low Profile Condensate Pump, 230 V, 60 Hz, 6' cord
J10-809W DEHUMIDISTAT - WALL MOUNT
The J10 Series Humidistats and Dehumidistats are designed to regulate the relative humidity of confined spaces by cycling humidifying or dehumidifying equipment. Designed for central systems, the J10 controls are made from high impact plastic with a brushed finish dial plate. The J10's nylon sensing element provides long life and accurate humidity control. The J10-809W dehumidistat is designed to be wall mounted and can be wired in series or parallel with a 24 volt nonelectric thermostat.

Features and Benefits

Strong plastic frame with integral switch eliminates the need to ground the control
Improved woven nylon sensing element provides a faster response time
Greater stability in set points over dramatic changes in relative humidity
Improved differential allowing 5% relative humidity
TBS04 TECH-SET™ 1/4" SPRING TUBE BENDER
This 1/4in spring-type tube bender works for soft copper and aluminum. The end bell design aids in quick tubing removal.
TBS10 TECH-SET™ 5/8" SPRING TUBE BENDER
This 5/8in spring-type tube bender works for soft copper and aluminum. The end bell design aids in quick tubing removal.
710-205 HYDRAULIC SNAP-ACTION LOW CAPACITY GAS VALVE
710 Series - Low Capacity
The Robertshaw® 710 Series Low Capacity Gas Valves feature an extremely compact control designed for low capacity and limited space applications. Features include three-position outlets, multi-positional capability and component replaceability.

Features and Benefits

Low capacity with 3-13/16”H x 4-21/32”L x 1-29/32” W dimensions
Gas cock dial marking Off - Pilot - On
Ambient temperature of -40°F to 175°F
Pilot outlet 1/4” tubing
Maximum inlet pressure 14” WC (0.5 PSI)
Standard NEMA terminals
Inlet filtered screen
Various gas types: natural, manufactured, mixed, LP, and LP/air mixtures
Multiple actuators available
RoHS compliant
032F0187 SPARE PART KIT MU 10/100
Service kit (NC); diaphragm assembly, O-ring, (4) screws, armature assembly, rubber gasket, refrigeration gasket, compression spring
HANDHELD SINGLE FLINT IGNITOR
Single flint ignitor is made of stainless steel with a large square hood and strong metal frame. It is lightweight, economical and dependable. It is the most popular ignitor in the industry and features a generous flint with a rotating wear-resistant file. Powertorch® single flint ignitor with replacement flint. Packaged 10 ignitors per case. Replaceable flints sold separately - PN 9004484.

Features
Most popular ignitor in the industry
Large square hood and strong metal frame
Long-life ignitor
Generous flint and rotating wear-resistant file
Uses low cost replacement flints
P170LB-1C PRESSURE CONTROL; 20"/100 PSIG LS 5 BU RANGE 100/425 PSIG
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170AA-118C 100/400# PSIG 5 BU DIFF. ADJ.35/200# PSI
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170MA-1C MAN RESET HS
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70AA-118C 100/400# DIFF. ADJ.; 35/200# 36CAP; 13
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70LB-6C 20/80 PSIG LS 13 36 RANGE 100/425 PSIG HS; W/KNOB
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
CCH0010MBACZ 1.0HP MED 1PH
CU CC SCRL 1.0HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 12,200 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0008MBACZ 0.8HP MED 1PH
CU CC SCRL 0.8HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 8,980 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0025MBACZ 2.5HP MED 1PH
CU CC SCRL 2.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 22,860 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0025LBACZ 2.5HP LOW 1PH
CU CC SCRL 2.5HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/1/60
Application Capacity* : 11,970 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.15
CCH0015MBACZ 1.5HP MED 1PH
CU CC SCRL 1.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 17,540 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
CCH0020MBACZ 2.0HP MED 1PH
CU CC SCRL 2.0HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 16,410 BTU/H
Refrigerant Type : R448A
AWEF Value : 7.6"
CCH0005MBACZ 0.5HP MED 1PH
CU CC SCRL 0.5HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 7,660 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
A605 TAPERED T FITTING FOR MANOMETERS, 0.25"
With the TPI A605 Tapered T Fitting for Manometers, you can measure pressure with your compatible TPI manometer or combustion analyzer. The T fitting is tapered and measures 0.25" (6.35 mm).

Features

Compatible with TPI 610, 615, 620 and 625 manometers (sold separately)
For use when performing pressure measurements or setting pressure switches
X3596 5 EXTRA DIAL PIN FOR PARAGON 208-240V DEFROST TIMER
The Paragon® 9045-00 and 9145-00 Universal Defrost Timers (UDT) are the only multi-voltage defrost timers engineered to industry refrigeration standards. Designed to withstand the most rigorous refrigeration applications, this control offers a real-time clock and 100 hours of power loss protection for both time and defrost schedules. Mechanism-only models also are available to fit in standard defrost timer enclosures.

Features and Benefits

Certified to UL873 standard for temperature-indicating and regulating equipment
Wires directly to 120V AC, 208V AC or 240V AC power sources without jumpers or switches
Rated to 30,000 cycles for refrigeration controllers with switches
Easy programming, easy set-up, set time, set defrost start and defrost end
Initiate 15 minute manual defrost
100 hours of power loss protection for both time and defrost schedule
Real-time clock
Lighted display shows defrost start time and duration
System status indicators

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.