Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
P70DA-1C 50/450# M/R OPEN-HI 36",# SW.
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170LB-6C 12/80 PSIG LS S BU RANGE 100/425 PSIG HS;
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170MA-1C MAN RESET HS
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P170AA-118C 100/400# PSIG 5 BU DIFF. ADJ.35/200# PSI
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70CA-2C 50/450#, 1/4 MALE FLARE
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
P70LB-1C SINGLE POLE DUAL PRESS, SPST, 20" WE TO 100 PSI LOW PRESS.100 PSI TO 500 PSI HIG
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
VPBM8V BLACKMAX® 8 CFM SPARKLESS DC VACUUM PUMP
Key Features:
• Lightweight (22.4 Lbs / 10.1 Kg)
• Compact, portable size (0.57 cu. ft.)
• 1 HP, variable speed, brushless DC motor
• 100 to 240VAC (50/60Hz) universal voltage
In-line 1/2″, 3/8″,1/4″ hose connection ports
Stores/operates in extreme temperatures
Auto shut-off solenoid valve
Analog vacuum gauge
Large vertical oil sight glass
Closed, hoist-type handle
15 Micron ultimate vacuum
Quiet Operation
VPBM4V BLACKMAX® 4 CFM SPARKLESS DC VACUUM PUMP
Key Features:
• Lightweight (18.2 Lbs / 8.25 Kg)
• Compact, portable size (0.48 cu. ft.)
• 1/2 HP, variable speed, brushless DC motor
• 100 to 240VAC (50/60Hz) universal voltage
• In-line 1/2″, 3/8″,1/4″ hose connection ports
• Stores/operates in extreme temperatures
• Auto shut-off solenoid valve
• Analog vacuum gauge
• Large vertical oil sight glass
• Closed, hoist-type handle
• 15 Micron ultimate vacuum
• Quiet Operation
A421GBF-02C ELECTRONIC SINGLE STAGE
Features
Features A421 Standard model
Control Front Panel LCD:
Displays the temperature, parameters, and status and allows you to adjust the backlight intensity for ambient light conditions. Custom icons display the system and control status.
Basic and Advanced Programming Menu:
Provides two levels of parameter adjustment and control setup, allowing you to set up advanced features in one menu and easily adjust basic parameters in the other menu.
On/Off Temperature Adjustment:
Allows you to select the temperature values at which the relay turns On and Off, which automatically defines the Heating or Cooling mode of operation.
Switch-Activated Temperature Setback:
Allows you to shift the On/Off temperature by an adjustable setback value. When a user-supplied switch closes the binary input control circuit, the control operates at the defined setback temperatures.
Adjustable Anti-Short Cycle Delay:
Allows you to select the minimum time the output relay remains off before the next on cycle; avoiding short cycling, hard starts, and nuisance overload outages on compressors and other inductive applications.
Adjustable Sensor Offset:
Allows you to adjust the displayed temperature to the actual sensed temperature.
Optional Restricted Adjustment Mode:
Allows you to restrict the On/Off adjustment to your defined temperature range.
Sensor Failure Mode:
Allows you to select the relay On/Off state in the event of a sensor or sensor wire failure.
Backlight Brightness Level:
Allows you to adjust the LCD backlight intensity.
Extra Features A421 Defrost model
Off-Cycle Defrost:
Allows you to shut off the refrigeration system for defined defrost time interval and frequency. You can also start or stop a manual only defrost offcycle.
Extra Features A421 Timer model
Free-Cooling and Ventilation:
Allows you to adjust for free-cooling and timed-ventilation, and provides over-cooling protection.
KASON 10056005005 STRIKE, DOOR LATCH, 1 3/4" TO 2 1/2" OFFSET, CHROME
A Kason 10056005005 Strike holds a reliable latch point to tighten the door seal and maintain consistent performance in high-volume foodservice settings.

Installing real OEM catches, latches and strikes supports precise alignment with existing hardware, promoting seamless fit and function across varying door offsets for true compatibility
Product Type: Door Latch Strike
Offset: 1 3/4" to 2 1/2"
Color: Chrome
TLVC2 DUAL VALVE CORE TOOL (1/4" SAE VALVES & AUTO R-134A VALVES)
This dual valve core remover and installer can remove and install 2 valve cores.
SVW NEW: WIRELESS SOLENOID VALVE ACCESSORY - OPERATES WITH CC220EW
Use this solenoid valve to accurately measure gas or liquid flowing through hoses. It can also manually or automatically charge or recover refrigerants.
VPBM12V BLACKMAX® 12 CFM SPARKLESS DC VACUUM PUMP
Key Features:
• Lightweight (23.2 Lbs / 10.8 Kg)
• Compact, portable size (0.57 cu. ft.)
• 1 HP, variable speed, brushless DC motor
• 100 to 240VAC (50/60Hz) universal voltage
• In-line 1/2″, 3/8″,1/4″ hose connection ports
• Stores/operates in extreme temperatures
• Auto shut-off solenoid valve
• Analog vacuum gauge
• Large vertical oil sight glass
• Closed, hoist-type handle
• 15 Micron ultimate vacuum
• Quiet Operation
BTCK BLACKMAX 3-PK TUBE CUTTER KIT: BTC100, BTC200, BTC350
Ideal for cutting soft or hard copper, brass, or aluminum tube used in HVAC/R applications.
VPBM6V BLACKMAX® 6 CFM SPARKLESS DC VACUUM PUMP
Key Features:
• Lightweight (19.1 Lbs / 8.6 Kg)
• Compact, portable size (0.48 cu. ft.)
• 1/2 HP, variable speed, brushless DC motor
• 100 to 240VAC (50/60Hz) universal voltage
• In-line 1/2″, 3/8″,1/4″ hose connection ports
• Stores/operates in extreme temperatures
• Auto shut-off solenoid valve
• Analog vacuum gauge
• Large vertical oil sight glass
• Closed, hoist-type handle
• 15 Micron ultimate vacuum
• Quiet Operation
A421ABC-02C ELECTRONIC SINGLE STAGE
Features
Features A421 Standard model
Control Front Panel LCD:
Displays the temperature, parameters, and status and allows you to adjust the backlight intensity for ambient light conditions. Custom icons display the system and control status.
Basic and Advanced Programming Menu:
Provides two levels of parameter adjustment and control setup, allowing you to set up advanced features in one menu and easily adjust basic parameters in the other menu.
On/Off Temperature Adjustment:
Allows you to select the temperature values at which the relay turns On and Off, which automatically defines the Heating or Cooling mode of operation.
Switch-Activated Temperature Setback:
Allows you to shift the On/Off temperature by an adjustable setback value. When a user-supplied switch closes the binary input control circuit, the control operates at the defined setback temperatures.
Adjustable Anti-Short Cycle Delay:
Allows you to select the minimum time the output relay remains off before the next on cycle; avoiding short cycling, hard starts, and nuisance overload outages on compressors and other inductive applications.
Adjustable Sensor Offset:
Allows you to adjust the displayed temperature to the actual sensed temperature.
Optional Restricted Adjustment Mode:
Allows you to restrict the On/Off adjustment to your defined temperature range.
Sensor Failure Mode:
Allows you to select the relay On/Off state in the event of a sensor or sensor wire failure.
Backlight Brightness Level:
Allows you to adjust the LCD backlight intensity.
Extra Features A421 Defrost model
Off-Cycle Defrost:
Allows you to shut off the refrigeration system for defined defrost time interval and frequency. You can also start or stop a manual only defrost offcycle.
Extra Features A421 Timer model
Free-Cooling and Ventilation:
Allows you to adjust for free-cooling and timed-ventilation, and provides over-cooling protection.


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.