Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
114N3594 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 4HP 3PH
114N3594 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 4HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0400UWL000Q

R448A/R449A Capacity range: 15220 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 3563W, AWEF 3.41

R404A/R507 Capacity range: 18280 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 3672W, AWEF 3.81
114N3578 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 2HP 3PH
114N3578 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 2HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0200UWK000Q

R448A/R449A Capacity range: 17070 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 2408W, AWEF 8.44

R404A/R507 Capacity range: 18870 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 2359W, AWEF 10.06
114N3595 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 5HP 3PH
114N3595 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 5HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0500UWL000Q

R448A/R449A Capacity range: 18620 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 4297W, AWEF 3.48

R404A/R507 Capacity range: 22070 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 4462W, AWEF 3.77
114N3584 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 3.5HP 3PH
114N3584 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 3.5HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0350UWK000Q

R448A/R449A Capacity range: 28890 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3826W, AWEF 9.22

R404A/R507 Capacity range: 31910 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3829W, AWEF 10.33
114N3591 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7HP 3PH
114N3591 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0700UWK000Q

R448A/R449A Capacity range: 55260 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6907W, AWEF 9.83

R404A/R507 Capacity range: 58470 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6912W, AWEF 10.45
114N3582 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 2.5HP 3PH
114N3582 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 2.5HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0250UWK000Q

R448A/R449A Capacity range: 22000 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3013W, AWEF 8.79

R404A/R507 Capacity range: 24040 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 2973W, AWEF 10.04
114N3592 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7.5HP 3PH
114N3592 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 7.5HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0750UWK000Q

R448A/R449A Capacity range: 66910 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 7665W, AWEF 10.28

R404A/R507 Capacity range: 72410 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 8089W, AWEF 10.66
114N3589 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 6HP 3PH
114N3589 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 6HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0600UWK000Q

R448A/R449A Capacity range: 50610 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6504W, AWEF 9.64

R404A/R507 Capacity range: 54180 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 6264W, AWEF 10.57
VIPER NICKEL SAFE ICE MACHINE CLEANER 16 OZ
ICE MACHINE CLEANERS
Until now, ice machine cleaners were nothing more than low tech phosphoric acid. Our Viper Ice Machine cleaner is formulated with an advanced blend of organic acids that will remove more scale faster than any other product of its kind. It is a stronger acidic cleaner and is lower in toxicity, non-fuming, less corrosive and environmentally preferred over phosphate based chemicals.

Approved for Nickel Plated Evaporators
Removes More Scale Buildup
Faster Acting Formula
Phosphate Free
11-193 ALUMINUM 1/4" TUBING 50' ROLL
The Robertshaw® aluminum tubing is versatile for all your replacement needs. It comes in a full range of sizes in 50 foot and 5 foot lengths.

Features and Benefits

Aluminum tubing meets ASTMB Standard #483
Uses a 1435 alloy with a 0.035" wall thickness
Tubing is rated at 90 PSI with an 11,000 tensile, 9500 yield and a 25% elongation
11-293 ALUMINUM 1/4" TUBING WITH FITTINGS 5' ROLL
The Robertshaw® aluminum tubing is versatile for all your replacement needs. It comes in a full range of sizes in 50 foot and 5 foot lengths.

Features and Benefits

Aluminum tubing meets ASTMB Standard #483
Uses a 1435 alloy with a 0.035" wall thickness
Tubing is rated at 90 PSI with an 11,000 tensile, 9500 yield and a 25% elongation
BTLH5E PREMIUM HYDRAULIC MUTLI-HEAD TUBE EXPANDER W/COLOR CODED HEADS FOR 3/8", 1/2", 5/8", 3/4", 7/8"
This tube expander kit can easily expand the ends of soft copper and aluminum tubing using the power of hydraulics (fluid compression). The premium, compact, cast-aluminum hydraulic expander tool is perfect for HVAC/R applications.
114N3588 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 5HP 3PH
114N3588 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 5HP 3PH
Compressor power supply [V]: 230/3/60
HRXM0500UWK000Q

R448A/R449A Capacity range: 41710 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 5406W, AWEF 9.06

R404A/R507 Capacity range: 45690 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 5430W, AWEF 9.64
114N3596 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 6HP 3PH
114N3596 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 6HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0600UWL000Q

R448A/R449A Capacity range: 20630 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 5385W, AWEF 3.26

R404A/R507 Capacity range: 25730 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 5513W, AWEF 3.53
114N3586 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 4HP 3PH
114N3586 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 4HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0400UWK000Q

R448A/R449A Capacity range: 34040 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 4455W, AWEF 9.40

R404A/R507 Capacity range: 36450 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 4596W, AWEF 9.62
114N3580 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 3HP 3PH
114N3580 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) MED 3HP 3PH
Compressor power supply [V]: 230/3/60
OP-HNXM0300UWK000Q

R448A/R449A Capacity range: 23320 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3187W, AWEF 9.92

R404A/R507 Capacity range: 25290 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =25°F), Power consumption 3187W, AWEF 9.92
114N3597 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 8HP 3PH
114N3597 OPTYMA™ OUTDOR SLIM (LOW AMBIENT KIT) LOW 8HP 3PH
Compressor power supply [V]: 230/3/60
LNYM0600UWL000Q

R448A/R449A Capacity range: 27310 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 6222W, AWEF 3.39

R404A/R507 Capacity range: 33350 BTU/hr (Ambient Temp. = 95°F , evaporating temperature =-10°F), Power consumption 6360W, AWEF 3.76
HVAC LEAK STOP PLUS U/V DYE (UP TO 1.5 TON UNIT) BOV DOMED CAN
PATENTED BOV DELIVERY METHOD

HVAC Leak Stop + U/V Dye bag-on-valve (BOV) aerosol does not contain refrigerant.
1 ounce can treats up to 1.5 tons.
Does not contain polymers, will not harm A/C system or components.
Additive package protects against future corrosion.
Compatible with all lubricants & refrigerants.
SM5412 9 WATT ALUMINUM UNIT BEARING MOTOR 115V CCWLE
For commercial and domestic refrigeration equipment, room and hood ventilators, evaporative coolers and various other equipment.

Features/Benefits

50/60Hz
Cast aluminum housing up to 16 watts
Hardware included
Overload protected
Permanent lubrication
Rotation determined by viewing opposite shaft end
Single rotation
Single speed, 1550 RPM
Sleeve bearings
Threaded mounting holes
Totally enclosed
UL® Approved
Universal mounting
SM5422 9 WATT ALUMINUM UNIT BEARING MOTOR 230V CCWLE
For commercial and domestic refrigeration equipment, room and hood ventilators, evaporative coolers and various other equipment.

Features/Benefits

50/60Hz
Cast aluminum housing up to 16 watts
Hardware included
Overload protected
Permanent lubrication
Rotation determined by viewing opposite shaft end
Single rotation
Single speed, 1550 RPM
Sleeve bearings
Threaded mounting holes
Totally enclosed
UL® Approved
Universal mounting
O12-1549 LOW PRESSURE 10" TO 100 PSI MANUAL RESET, HIGH PRESSURE 150 TO 450 PSI MANUAL RESET
The Ranco® Dual Pressure Controls combine the functions of a single high-pressure limit control and a single low-pressure control in one unit with a single pole, single throw (SPST) switch.

Features and Benefits

Convertible feature allows selection of manual or reset function when operating at high pressure (O12‑4833/O12-4834)
A wide range of high-pressure manual or automatic reset controls can be replaced (O12-4833 or O12‑4834)
A high-pressure limit is combined with suction pressure sensing to provide temperature control and/or pump down
High-limit adjustment screw
Low-pressure differential and range adjusting screws
Selector screw for manual or automatic
Reset button
Low-pressure scale plate
High-impact plastic cover with center mount screw
High-pressure scale plate
Super Cap® capillary protection system
Color-coded for easy identification of pressure line
High-side capillary flare nut (silver)
Low-side capillary flare nut (brass)
O12-1594 DUAL PRESSURE CONTROL LOW PRESSURE 10" TO 100 PSI MANUAL RESET, HIGH PRESSURE 150 TO 450 PSI MANUAL RESET
The Ranco® Dual Pressure Controls combine the functions of a single high-pressure limit control and a single low-pressure control in one unit with a single pole, single throw (SPST) switch.

Features and Benefits

Convertible feature allows selection of manual or reset function when operating at high pressure (O12‑4833/O12-4834)
A wide range of high-pressure manual or automatic reset controls can be replaced (O12-4833 or O12‑4834)
A high-pressure limit is combined with suction pressure sensing to provide temperature control and/or pump down
High-limit adjustment screw
Low-pressure differential and range adjusting screws
Selector screw for manual or automatic
Reset button
Low-pressure scale plate
High-impact plastic cover with center mount screw
High-pressure scale plate
Super Cap® capillary protection system
Color-coded for easy identification of pressure line
High-side capillary flare nut (silver)
Low-side capillary flare nut (brass)
BRO - VPS-216 AH PILLOW BLOCK BEARING UNIT
Pillow Block Bearing; 2 Bolt Pillow Block; 1" Bore; 1-7/16" Base to Center Height; Set Screw Mount; Ball Bearing; Relubricatable; Cast Iron; Non-Expansion
1980-060 1980 SNAP-FIT THERMOCOUPLE 60" (152CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
1980-018 1980 SNAP-FIT THERMOCOUPLE 18" (45CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
1980-012 1980 SNAP-FIT THERMOCOUPLE 12" (30CM)
The Robertshaw® 1900 Series Thermocouples include either a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. It is also found on many LP gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame. The Robertshaw 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits
Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
1980-030 1980 SNAP-FIT THERMOCOUPLE 30"
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
1980-072 1980 SNAP-FIT THERMOCOUPLE 72" (182CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.