Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
ECONOMICAL SINGLE-STAGE PRESSURE REGULATOR 601-15-520
Model 601 single-stage regulator is designed to be compact and economical, but with features typically available in more expensive models. It is used where weight, cost and size are factors. Features a brass body, 50mm ABS plastic dual scale gauges and one-piece encapsulated seat design with internal filter and PTFE Teflon® seat. This model is UL® listed.

Features
Compact design at an economical price
For applications where weight, cost and size are critical factors
Higher end features at an economical price
Brass body and bonnet for longer service life
Large plastic knob for easy grip and precise adjustments
50mm ABS plastic dual scale easy-to-read gauges
One-piece encapsulated seat design with internal filter to protect the PTFE Teflon® seat from particulate contamination
Neoprene diaphragm for improved pressure control
UL® listed
S903758 IGNITER KIT
Supco® igniters offer an efficient , stronger, reliable hot surface Silicon Carbide design.

Features/Benefits

18 gauge copper high temperature fiberglass insulated lead wires
Exact replacement hot surface igniters
Faster time to temperature response
Lower power consumption
Stronger more durable design
Superior gas lighting ability
DP252402 CONTACTOR 25A 240V 2 POLE
CONTACTOR, 240V, 25A, 2, 35A, #10-32 SCREWS

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Application Low drop out voltage making them ideal for any air conditioning heating and refrigeration application
MBHP5E R-22, 404A, 410A GAUGES & 5' PREMIUM BV HOSES
This 2-valve manifold and gauge set has an anodized-aluminum block body with 1/4in SAE, 45° fittings and an extra access port in the center with a Schrader valve and hanging hook.
8045-00 MECHANICAL DEFROST TIMER 120V AC TIME TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
DP404803 CONTACTOR 40A 480V 3 POLE
CONTACTOR, 3 PL, BX LUG, 50A, 480V, 40A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
41-802N UNIVERSAL HOT SURFACE IGNITOR
Robertshaw® IgnitorPro™ Universal Ignitors are a durable and versatile product contractors can keep on
hand to ensure quick, reliable repairs. These ignitors include all mounting brackets and hardware.

Versatile:
- Replace more than 150 ignitors from leading OEMs
- The perfect truck stock items-minimal inventory
- Round and flat blade designs available
Easy to install: Include all mounting brackets and hardware
Reliable: Constructed with silicon nitride, the new industry standard for durability
- Fewer callbacks
- More repeat business for new installations and preventive maintenance
SFC200240 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
1980-024 1980 SNAP-FIT THERMOCOUPLE 24" (60CM)
The Robertshaw® 1980 Series Snap-Fit® Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures.

Features and Benefits

Easy burner installation with attached threaded nut
Stainless steel outer jacket for long life and resistance to heat blistering
Combination of copper and nickel alloys for good electrical conductivity
Mica washer to insulate from shorting conditions
Tinnerman clip included
Various lengths available for multiple applications
LCD35+7.5X440 LB OVAL DUAL RUN CAPACITOR
CAPACITOR, RUN, OVAL DUAL, 35+7.5 MFD, 440V

10,000 AFC pressure sensitive short circuit interrupting capability
Continuous life tested, oil leak tested and dielectric tested for insulation effectiveness
Life tested to 85°C operating temperature for 10,000 cycles
Manufactured with thick polypropylene foil to handle increased operating temperatures, PCB-free oil to prevent over-heating
Meets EIA-456A accelerated life test at 70°C for 60,000 hours
US and Canada UL Approved (C22.2NO.190)
IM2 INSPECTION MIRROR 1 X 2 OVAL
Telescoping tools match clip, magnet and inspection mirrors

Features/Benefits

1" x 2" oval glass mirror
Carry pouch included
Double ball joint head adjustment
Extendable/retractable design
Glass mirrors
Magnified glass mirror available with IM6
Pocket clip
X3596 5 EXTRA DIAL PIN FOR PARAGON 208-240V DEFROST TIMER
The Paragon® 9045-00 and 9145-00 Universal Defrost Timers (UDT) are the only multi-voltage defrost timers engineered to industry refrigeration standards. Designed to withstand the most rigorous refrigeration applications, this control offers a real-time clock and 100 hours of power loss protection for both time and defrost schedules. Mechanism-only models also are available to fit in standard defrost timer enclosures.

Features and Benefits

Certified to UL873 standard for temperature-indicating and regulating equipment
Wires directly to 120V AC, 208V AC or 240V AC power sources without jumpers or switches
Rated to 30,000 cycles for refrigeration controllers with switches
Easy programming, easy set-up, set time, set defrost start and defrost end
Initiate 15 minute manual defrost
100 hours of power loss protection for both time and defrost schedule
Real-time clock
Lighted display shows defrost start time and duration
System status indicators
AB90 90° 1/4" SAE FM QC X 1/4" SAE M
This 1-piece MICRO-SEAL™ quick coupler hose adapter features 1/4in SAE female x 1/4in SAE male connectors with a 90° female design.
DP601203 CONTACTOR 60A 120V 3 POLE
CONTACTOR, 3 PL, BX LUG, 75A, 120V, 60A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
SF8429 TEE COPPER, 3/4" OD, SWAGED ONE SIDE X 1/4" MALE FLARE ON BRANCH
¾" x 3" Tube, expanded to ¾" ID on one side, ¼" Male Flare w/ Cap Wrench & Core

Features/Benefits

¼" SAE Male Flare
Brass cap with Neoprene O-ring
Stainless steel valve core, suitable for all refrigerants
SUD113 COPPER DRIER
SUPCO® Cooper Driers are high quality, high capacity original equipment components for use on domestic and commercial refrigerators, freezers, and air conditioners.

Features/Benefits

100% XH-9 Beaded Molecular Sieve
Compatible with all refrigerants (including R290 & R600A)
Copper shells and end tubes
Easy break off grooved ends
Hermetically sealed
High capacity
SFC200365 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
060L2152 KPU 19 THERMOSTAT ROOM SENSOR SPDT M/10
KPU 19 - Thermostats
The KPU 19 thermostats are designed for easy installation and service with bottom and rear knockouts, differential adjustment dial,
a tamper-resistant design, and a robust thermoplastic housing.


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.