183A/265 KIT DIGITAL MULTIMETER AND CLAMP-ON METER KIT
To use it's as simple as touching the plastic tip onto any connecting point or move it along an insulated wire. You will be notified if AC voltage is found by a sounded alarm and the plastic tip will glow a bright red. It will turn off at the next break in circuit or wire.

Features

Prevents electrical shocks
Measures: 50 to 1,000 VAC
No switch is required, always ready for use
Sound and bright red glow indicates voltage, buzzer will only react to AC voltage and not static electricity
UL listed
Lifetime Warranty
Applications

AC Voltage in Switches
AC Voltage in wall outlets
AC Voltage in junction boxes
9145-00 UNIVERSAL DEFROST TIMER - AUTO VOLTAGE TIME / TEMPERATURE OR PRESSURE TERMINATION
The Paragon® 9045-00 and 9145-00 Universal Defrost Timers (UDT) are the only multi-voltage defrost timers engineered to industry refrigeration standards. Designed to withstand the most rigorous refrigeration applications, this control offers a real-time clock and 100 hours of power loss protection for both time and defrost schedules. Mechanism-only models also are available to fit in standard defrost timer enclosures.

Features and Benefits

Certified to UL873 standard for temperature-indicating and regulating equipment
Wires directly to 120V AC, 208V AC or 240V AC power sources without jumpers or switches
Rated to 30,000 cycles for refrigeration controllers with switches
Easy programming, easy set-up, set time, set defrost start and defrost end
Initiate 15 minute manual defrost
100 hours of power loss protection for both time and defrost schedule
Real-time clock
Lighted display shows defrost start time and duration
System status indicators
HS16001 THE ACID TEST
Use to detect the presence and formation of acid in air conditioning and refrigeration systems

Features/Benefits

4 complete tests in each kit
Accurate results in seconds
Easy to use - no complicated charts
For use with all refrigerants
Non-Flammable
Non-Toxic
X3596 5 EXTRA DIAL PIN FOR PARAGON 208-240V DEFROST TIMER
The Paragon® 9045-00 and 9145-00 Universal Defrost Timers (UDT) are the only multi-voltage defrost timers engineered to industry refrigeration standards. Designed to withstand the most rigorous refrigeration applications, this control offers a real-time clock and 100 hours of power loss protection for both time and defrost schedules. Mechanism-only models also are available to fit in standard defrost timer enclosures.

Features and Benefits

Certified to UL873 standard for temperature-indicating and regulating equipment
Wires directly to 120V AC, 208V AC or 240V AC power sources without jumpers or switches
Rated to 30,000 cycles for refrigeration controllers with switches
Easy programming, easy set-up, set time, set defrost start and defrost end
Initiate 15 minute manual defrost
100 hours of power loss protection for both time and defrost schedule
Real-time clock
Lighted display shows defrost start time and duration
System status indicators
SSGSS4 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
TFXMJ TRADEFOX FUSED MULTI JUMPER
Invented by an HVAC technician, this pocket-sized tool allows you to engage multiple circuits at the same time during system troubleshooting. Plus, it has removable banana plugs so you can connect your volt meter to create an extended fused jumper wire.

Features/Benefits

3 Amp Fusible Link
Convienient, space saving size
Female banana terminals
Magnetic jumper leads w/ removable rubber caps
Part of our SUPCO® TradeFox™ Technician-Invented product line
Removable banana plugs
O12-1549 LOW PRESSURE 10" TO 100 PSI MANUAL RESET, HIGH PRESSURE 150 TO 450 PSI MANUAL RESET
The Ranco® Dual Pressure Controls combine the functions of a single high-pressure limit control and a single low-pressure control in one unit with a single pole, single throw (SPST) switch.

Features and Benefits

Convertible feature allows selection of manual or reset function when operating at high pressure (O12‑4833/O12-4834)
A wide range of high-pressure manual or automatic reset controls can be replaced (O12-4833 or O12‑4834)
A high-pressure limit is combined with suction pressure sensing to provide temperature control and/or pump down
High-limit adjustment screw
Low-pressure differential and range adjusting screws
Selector screw for manual or automatic
Reset button
Low-pressure scale plate
High-impact plastic cover with center mount screw
High-pressure scale plate
Super Cap® capillary protection system
Color-coded for easy identification of pressure line
High-side capillary flare nut (silver)
Low-side capillary flare nut (brass)
SF9614 TEE BRASS, 1/4" MALE FLARE X 1/4" MPT X 1/4" MALE FLARE ON BRANCH - 2 EA
SF9600 Series ¼" flare forged access tees with forged brass tee and ¼" flares are threaded for valve cores

Features/Benefits

¼" male flare x ¼" MPT x ¼" male flare access on branch
One cap
One valve core
SSGSS5 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
SF1819 ACCESS BODY, 1/8" MPT ELBOW
¼" Male Flare X ⅛" MPT Elbow w/ Wrench Cap & Core

Features/Benefits

¼" SAE Male Flare
⅛" MPT
Brass cap with Neoprene O-ring
Stainless steel valve core, suitable for all refrigerants
SIG106 FURNACE IGNITER
SIG106 - Furnace Ignitor

Exact replacement silicon carbide round ignitor

Features & Benefits:

Exact replacement hot surface ignitors
Superior gas lighting ability
Lower power consumption
18 gauge copper high temperature fiberglass insulated lead wires
Supco® round igniters offer an efficient , stronger, reliable hot surface Silicon Carbide design
Faster time to temperature response
Stronger more durable design
More robust in transit
Higher resistance to oxidation
Longer usable life
A085 SILICONE TEST LEAD SET, UL LISTED
Test Leads with Threaded Tips and Screw on Alligator Clips.
SSGSS2 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
SSN2533 SURFACE IGNITER
SSN2533--Silicon Nitride Ignitor replaces Heil Quaker (ICP) 1172533

This Igniter is used on many ArcoAire®, Comfortmaker®, Heil®, Tempstar®, and Whirlpool® furnaces.
785-001 PILOT RELIGHT KIT
The Robertshaw® 785 Series Automatic Pilot Relight Kits are designed for use on rooftop heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other commercial, industrial, and residential appliances where the problem of pilot outage may occur. It should only be applied to those systems which already incorporate the necessary pilot-safety control system.

Features and Benefits
Kit Includes: Ignitor Assembly & Mounting Bracket
SF9603 TEE BRASS, 1/4" MALE FLARE X 1/4" MALE FLARE X FEMALE FLARE ON BRANCH
Tee connector with 1/4" male flare access and valve core X 1/4" male flare access X 1/4" female flare with depressor tip.

Features/Benefits

¼" male flare with valve core and cap x ¼" male flare x ¼" female flare nut with depressor tip on the branch
All brass connector tee
SSGSS3 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
SPP5E E SERIES HARD START
START, HARD, 170 TO 277V, 1/3 TO 2 HP

Backup electronic timing circuit to protect the compressor
Can be used on PSC and CSIR type compressors
Easy 2-wire installation
Electronic potential relay (EPR) technology, Instant re-start, voltage sensing
NATE recognized (course #1867-0002)
SSGFM3 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
SF3602 ACCESS FITTING 1/4", 3/16", 1/8" BUSHINGS - 6 EA
Line service valve ¼" copper tubing, 3/16" & ⅛" copper bushings, wrench cap & core

Features/Benefits

¼" Copper Tubing, 3/16" and ⅛" Copper Bushings
Made of CDA 360 brass
Wrench Cap and Core
SPP6E E SERIES HARD START
START, HARD, 170 TO 277V, 1/2 TO 3 HP

Backup electronic timing circuit to protect the compressor
Can be used on PSC and CSIR type compressors
Easy 2-wire installation
Electronic potential relay (EPR) technology, Instant re-start, voltage sensing
NATE recognized (course #1867-0002)
MERV 10 FILTER QZ116241H10
Size: 16 X 24 X 1
The unique design and construction of the Q-Air throwaway polyester panel filter eliminates air bypass and optimizes air filtration. The 100% polyester media is upgraded from fibreglass and the high-quality chipboard frame, made from recycled content, ensures durability. The specialized adhesive and filter frame construction improves airborne particulate removal, resulting in better air quality.


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results