CC220 COMPUTE-A-CHARGE® 220 LB ELECTRONIC SCALE, 0.25 OZ ACCURACY & RESOLUTION WITH HARD CASE - 8.75 INCH PLATFORM
This COMPUTE-A-CHARGE refrigerant charging/recovery scale features a high capacity of 220lbs (100kg). With accuracy and resolution of 0.25oz (7.39mL) and calibrated to strict NIST standards, this charging scale offers the most advanced load-cell technology, making it an industry-leading scale in HVAC/RR applications.
ECONOMICAL SINGLE-STAGE PRESSURE REGULATOR 601-15-520
Model 601 single-stage regulator is designed to be compact and economical, but with features typically available in more expensive models. It is used where weight, cost and size are factors. Features a brass body, 50mm ABS plastic dual scale gauges and one-piece encapsulated seat design with internal filter and PTFE Teflon® seat. This model is UL® listed.

Features
Compact design at an economical price
For applications where weight, cost and size are critical factors
Higher end features at an economical price
Brass body and bonnet for longer service life
Large plastic knob for easy grip and precise adjustments
50mm ABS plastic dual scale easy-to-read gauges
One-piece encapsulated seat design with internal filter to protect the PTFE Teflon® seat from particulate contamination
Neoprene diaphragm for improved pressure control
UL® listed
SLS170 THERMOSTAT AUTO RESET
The SLS series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

Auto reset
CSA approved
Offered in a broad temperature range to cover most heating applications
UL® recognized

Terminals: 45° angle ¼"
Cut out temp ( °F): 170 °F
Cut in temp ( °F): 130 °F
Differential °: 40 °F
S903758 IGNITER KIT
Supco® igniters offer an efficient , stronger, reliable hot surface Silicon Carbide design.

Features/Benefits

18 gauge copper high temperature fiberglass insulated lead wires
Exact replacement hot surface igniters
Faster time to temperature response
Lower power consumption
Stronger more durable design
Superior gas lighting ability
SHL505 PLENUM THERMOSTAT
The SHL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

36T Electrical Ratings
CSA approved
Direct OEM replacements
Economical
L140-40 SPST
SF3603 LINE SERVICE VALVE, 3/16" OD TUBE, WITH WRENCH - 6CAP
Line Service Valve 3/16" Copper Tubing, Wrench Cap and Core

Features/Benefits

3/16" Copper Tubing
Made of CDA 360 brass
Wrench Cap and Core
A12-701 CONSTANT CUT-IN TEMPERATURE CONTROL
The Ranco® A12 and 9531 Series Constant Cut-in Temperature Controls are designed to switch electrical components of refrigeration systems in response to sensed temperatures.

Features and Benefits

Laser-welded stainless steel bellows
Fixed or adjustable temperature settings
High-amperage contacts
Pneumatic action provided by vapor-filled capillary or capillary with bulb sensing elements
Constant On or Off positions available
Choice of mounting brackets, adjustment ranges and cams, and slotted or flatted shafts
Standard 1/4” quick-connect terminals with optional screw terminals
P70CA-1C PRESSURE CONTROL, SPST 20IN/100P
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
8045-00 MECHANICAL DEFROST TIMER 120V AC TIME TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
725L COMBUSTIBLE GAS LEAK DETECTOR
40 PPM methane sensitivity, detects combustible gases including: Methane, Butane, Propane, Gasoline, Diesel and Kerosene. Tick rate can be nullified to eliminate background gas concentration and pinpoint the leak source.

40ppm methane sensitivity and bearing defects
Trace natural gas lines and fittings for leaks frame to failure
Check gas equipment for leaks
Test propane tanks, fittings, lines, and heaters for leaks
Check propane tanks, fitting lines, and heaters for leaks
Test confined spaces for gas build-up
Q104 SEQUENCER
Q Series Sequencer, field proven for controlling the operation of heating elements and/or blower motors in electric, gas or oil heat systems. This sequencer has 2 switches & turns on at 30-90 seconds, and off at 1-30 seconds.

Features/Benefits

24 volt control circuit
Five second delay between all subsequent stages, unless they function together
UL® and CSA® approved

Off: 1 - 30 Seconds
On: 30 - 90 Seconds
CS216-259X110 START CAPACITOR
CAPACITOR, START, 216 – 259 MFD, 110V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-7/16 in

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.