Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
AX56QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
034L0052 KVL 35 CRANKCASE PRES. REG. M/7
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
AX21QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
BX42QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
034N0083 CPCE 15 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
A421GBF-02C ELECTRONIC SINGLE STAGE
Features
Features A421 Standard model
Control Front Panel LCD:
Displays the temperature, parameters, and status and allows you to adjust the backlight intensity for ambient light conditions. Custom icons display the system and control status.
Basic and Advanced Programming Menu:
Provides two levels of parameter adjustment and control setup, allowing you to set up advanced features in one menu and easily adjust basic parameters in the other menu.
On/Off Temperature Adjustment:
Allows you to select the temperature values at which the relay turns On and Off, which automatically defines the Heating or Cooling mode of operation.
Switch-Activated Temperature Setback:
Allows you to shift the On/Off temperature by an adjustable setback value. When a user-supplied switch closes the binary input control circuit, the control operates at the defined setback temperatures.
Adjustable Anti-Short Cycle Delay:
Allows you to select the minimum time the output relay remains off before the next on cycle; avoiding short cycling, hard starts, and nuisance overload outages on compressors and other inductive applications.
Adjustable Sensor Offset:
Allows you to adjust the displayed temperature to the actual sensed temperature.
Optional Restricted Adjustment Mode:
Allows you to restrict the On/Off adjustment to your defined temperature range.
Sensor Failure Mode:
Allows you to select the relay On/Off state in the event of a sensor or sensor wire failure.
Backlight Brightness Level:
Allows you to adjust the LCD backlight intensity.
Extra Features A421 Defrost model
Off-Cycle Defrost:
Allows you to shut off the refrigeration system for defined defrost time interval and frequency. You can also start or stop a manual only defrost offcycle.
Extra Features A421 Timer model
Free-Cooling and Ventilation:
Allows you to adjust for free-cooling and timed-ventilation, and provides over-cooling protection.
AX52QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
034N0084 CPCE 22 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0097 KVR 15 CONDENSING PRES. REG. M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
BX64QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
060-5244 KPU6B PRESSURE SWITCH M/14
KPU - Pressure Switches
KPU pressure switches are designed to be contractor friendly and used in refrigeration and air-conditioning systems to protect the systems
from excessively low suction or high discharge pressure. They can also be applied to start and stop compressors and the fans of air-cooled
condensers. KPU pressure switches, in single and dual versions, cover a comprehensive range of applications and are designed for use with
Fluorinated and non-aggressive refrigerants. Most KPU pressure controls can be used with R-410a systems with only a few code numbers.
AX46QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
CCH0027MBACZ 2.7HP MED 1PH
CU CC SCRL 2.7HP 208-230/1/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/1/60
Application Capacity* : 27,360 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
SF9602 TEE COPPER, 1/4" MALE FLARE X 1/4" MALE FLARE X FEMALE FLARE ON BRANCH - 2 EA
Tee connector with depressor tip and one valve core along the straight length, and an additional valve core at a 90° angle.

Features/Benefits

¼" male flare with valve core x ¼" male flare x ¼" female flare nut with depressor tip on the branch
CCH0025MCACZ 2.5HP MED 3PH
CU CC SCRL 2.5HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/3/60
Application Capacity* : 22,860 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
023Z1014 BURN-OUT FILTER DRIER DAS 306SVV M/8
DCL/DCB/DAS/DCR - Filter Driers
Danfoss lter driers function as simple drop-in replacements for most driers sold in the aftermarket or installed on equipment by
manufacturers. All Danfoss lter driers are constructed with a solid core design to maximize moisture removal while minimizing pressure
drop. These driers use a mixture of molecular sieve and activated alumina to both adsorb system moisture and capture acid and prevent
solid contaminants from entering the system. The Danfoss 1.5 cubic inch hermetic lter drier can be used in hydrocarbon systems to provide
exceptional protection while minimizing charge requirements.
WELDING AND BRAZING TIP NO.1 5090-1
Model 5090 is a one-piece acetylene tip for welding/brazing torches. This tip is manufactured using environmentally-friendly tellurium copper that has excellent machining properties resulting in a higher quality tip. It is precision drilled and swaged for more precise and consistent flames. Model 5090 uses a universal separable tip tube and mixer system for sizes 0-10, eliminating the expense of using a different mixer for every tip size. The tip has a metal-to-metal contact seat virtually eliminating the possibility of leaks and the need for thread sealants. Conveniently vacuum-packed for point-of-purchase display.

Features
Constructed of tellurium copper
Welding and brazing tip for use with acetylene
Metal-to-metal seat virtually eliminates leaks
Precision drilled and swaged for more precise and consistent flames
Excellent machining properties yields a higher quality tip
Uses Harris universal mixer sizes 0-10
Marked with Harris logo and tip size for easy identification
One year warranty
Conveniently packaged for point-of-purchase display
SSN2901 SINI FURNACE IGNITER
120 Volt Gas Furnace Hot Surface Ignitor

Connection: Molex
Voltage: 120VAC
SSN2000 SiNi UNIVERSAL IGNITER
Universal round silicon nitride igniter kit. Includes brackets and hardware to replace hundreds of OEM furnace and boiler igniters

Rated Voltage: 120V +10% -15%, 50/60 Hz
Cold Resistance: 9 to 17 Ohms
Temperature @ 102V +/-5V: 1976°F / 1080°C
Temperature @ 120V +/- 5V: 2156°F / 1180°C
Steady State Current: 0.8 to 2.0 Amps Maximum @ 120 Volts
Igniter Material: Silicon_Nitride
Probe Length from Bracket: 2.25 Inches
Wire Length: 15.5 Inches
SF8428 TEE COPPER, 5/8" OD, SWAGED ONE SIDE X 1/4" MALE FLARE ON BRANCH
5/8" x 3" Tube, expanded to 5/8" ID on one side, 1/4" Male Flare w/ Cap Wrench & Core

Features/Benefits

¼" SAE Male Flare
Brass cap with Neoprene O-ring
Stainless steel valve core, suitable for all refrigerants
41-404 HOT SURFACE FURNACE IGNITOR (CARBIDE) IG404
The Robertshaw® Carbide Series Hot Surface Ignitors deliver dependable ignition in heating systems of every description: furnaces, boilers, rooftop heaters, infrared burners, unit heaters, water heaters, and many other types of HVAC equipment. Packaged with special mounting adaptors.

Features and Benefits

Made from high-purity recrystallized silicon carbide. (Crystar™) which combines physical and thermal strength with stable electrical properties
Designed to reach ignition temperature(s) within 17 seconds
Have 18-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity
Manufactured with lead wires enclosed in a special high-temperature fiberglass insulation providing electrical protection
Operate at 120V AC. Some modules are rated for 208/240V input, however, the voltage to the ignitor is stepped down to 120V AC
SLS170 THERMOSTAT AUTO RESET
The SLS series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

Auto reset
CSA approved
Offered in a broad temperature range to cover most heating applications
UL® recognized

Terminals: 45° angle ¼"
Cut out temp ( °F): 170 °F
Cut in temp ( °F): 130 °F
Differential °: 40 °F
CCH0035LBACZ 3.5HP LOW 1PH
CU CC SCRL 3.5HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10.0 °F
Voltage : 208-230/1/60
Application Capacity* : 14,040 BTU/H
Refrigerant Type : R448A
AWEF Value : 3.15
TRADEFOX TFXJK FUSED MULTI JUMPER WITH SELECTOR SWITCHES
The Jumper King° allows you to quickly bypass any low voltage thermostat regardless of terminal style. This patent-pending all-in-one kit comes with everything you need to locate low-voltage shorts and eliminate compressor short cycling.

Features/Benefits

2-Spade Adapters, Jumper King° Thermostat Bypass Tool, Hard Carrying Case
6-Alligator Clips, 6-Magnetic Tips, 6-Jumper Leads, 6-Self Piercing Insulation Tips
For Use on low voltage circuits only (0-30VAC/VDC)
Four types of interchangeable tips: spade adapters, alligator clamps, magnetic tips and self-piercing insulation tips
Inovative selector switches to activate leads/circuits of your choosing at any time
No batteries required - powered by the low voltage in theA/C unit
Rugged unit has a rubberized boot, a magnet and fold-out hook for convenient mounting
Will never short out - contains a resettable popper fuse
Works on multiple stage units including heat pumps

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.