ROBERTSHAW RS8210 MULTI-STAGE 2 HEAT / 1 COOL NON-PROGRAMMABLE THERMOSTAT
RS8000 Pro-Series Non-Programmable Wall Thermostat
Contractors can offer owners easy, yet powerful and reliable two-stage heating and one-stage cooling control in a simple, modern design with the RS8210 non-programmable wall thermostat.
Multi-Stage - 2 Heat / 1 Cool

• Large terminal blocks for easy installation
• Universal sub-base
• Quick access menu button
• Contractor/technician setup menu Simple, yet powerful control.
• Large, easy-to-read 4.6-square-inch blue backlit display
• 24V AC Powered OR Battery Operation (Included)
• 6Year Limited Warranty
• Easy-access front-load battery compartment
• Adjustable temperature differential (swing) for energy optimization and maximum system life
• Adjustable room temperature calibration
• Adjustable setpoint limits
• Filter change reminder
• Five-minute selectable on/off compressor delay protection for short-cycling prevention
• Separate O and B terminals
O10-1401 RANCO SINGLE LOW PRESSURE CONTROL | SPST OPENS LOW | 1/4" SAE MALE FLARE
The Ranco® O Series Single Low Pressure Controls offer a variety of pressure ranges and switch action to provide maximum application flexibility.

Features and Benefits

Controls available for most refrigerant types
High-amp rated switch (SPST) design (O10-1402/O10-1483)
Super Cap® capillary vibration protection system
Non-conductive front cover with captive screw
Adjustable differential and range
Easy-to-read scale plate
Vibration cone (absorbs and reduces vibration away from brazed joint)
Low mass copper alloy capillary tube (reduces capillary stress caused by equipment vibration)
The O16-624 control has additional features:

Compatible with refrigerants 134A, 401A, 401B, 402A, 402B, 403A, 403B and 404A
41-403 HOT SURFACE FURNACE IGNITOR (CARBIDE)
The Robertshaw® Carbide Series Hot Surface Ignitors deliver dependable ignition in heating systems of every description: furnaces, boilers, rooftop heaters, infrared burners, unit heaters, water heaters, and many other types of HVAC equipment.

Features and Benefits

Made from high-purity recrystallized silicon carbide. (Crystar™) which combines physical and thermal strength with stable electrical properties
Designed to reach ignition temperature(s) within 17 seconds
Have 18-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity
Manufactured with lead wires enclosed in a special high-temperature fiberglass insulation providing electrical protection
Operate at 120V AC. Some modules are rated for 208/240V input, however, the voltage to the ignitor is stepped down to 120V AC.
40.95 39.00 39.0 CAD
41-429N 120V SILICON NITRIDE DIRECT REPLACEMENT IGNITOR FOR YORK S-102545231000
Robertshaw® offers direct replacements for several leading OEM brands. These ignitors are constructed with sturdy, long-lasting silicon nitride for maximum longevity. The Robertshaw 41-429N is a 120V Direct Replacement for York S-102545231000 with a 4.28 inch wire length and 1.46 inch insulator.
37.80 36.00 36.0 CAD
HP5NG (3-PK) 5' R,Y,B, PREMIUM HOSE
Safely and efficiently charge, recover, and evacuate CFC, H/CFC, HFC, HFO, R410a, R134a, and R12234yf refrigerants in residential and commercial HVAC/R systems with this hose kit. In addition, this convenient hose kit comes with three hoses (red, blue, and yellow) and features working pressure of 800 psi and ¼" SAE female fittings.
SUD115 COPPER DRIER
SUPCO® Cooper Driers are high quality, high capacity original equipment components for use on domestic and commercial refrigerators, freezers, and air conditioners.

Features/Benefits

100% XH-9 Beaded Molecular Sieve
Compatible with all refrigerants (including R290 & R600A)
Copper shells and end tubes
Easy break off grooved ends
Hermetically sealed
High capacity
TFXNPB NITRO PURGE BOOT
BOOT, NITROGEN, PURGE, 5 IN, HVAC/R

TFXMJ TRADEFOX FUSED MULTI JUMPER
Invented by an HVAC technician, this pocket-sized tool allows you to engage multiple circuits at the same time during system troubleshooting. Plus, it has removable banana plugs so you can connect your volt meter to create an extended fused jumper wire.

Features/Benefits

3 Amp Fusible Link
Convienient, space saving size
Female banana terminals
Magnetic jumper leads w/ removable rubber caps
Part of our SUPCO® TradeFox™ Technician-Invented product line
Removable banana plugs
O12-1549 LOW PRESSURE 10" TO 100 PSI MANUAL RESET, HIGH PRESSURE 150 TO 450 PSI MANUAL RESET
The Ranco® Dual Pressure Controls combine the functions of a single high-pressure limit control and a single low-pressure control in one unit with a single pole, single throw (SPST) switch.

Features and Benefits

Convertible feature allows selection of manual or reset function when operating at high pressure (O12‑4833/O12-4834)
A wide range of high-pressure manual or automatic reset controls can be replaced (O12-4833 or O12‑4834)
A high-pressure limit is combined with suction pressure sensing to provide temperature control and/or pump down
High-limit adjustment screw
Low-pressure differential and range adjusting screws
Selector screw for manual or automatic
Reset button
Low-pressure scale plate
High-impact plastic cover with center mount screw
High-pressure scale plate
Super Cap® capillary protection system
Color-coded for easy identification of pressure line
High-side capillary flare nut (silver)
Low-side capillary flare nut (brass)
SFC210275 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SF9603 TEE BRASS, 1/4" MALE FLARE X 1/4" MALE FLARE X FEMALE FLARE ON BRANCH
Tee connector with 1/4" male flare access and valve core X 1/4" male flare access X 1/4" female flare with depressor tip.

Features/Benefits

¼" male flare with valve core and cap x ¼" male flare x ¼" female flare nut with depressor tip on the branch
All brass connector tee
PHLIPBIT SQ2-PH2 RED/BLUE 6" DOUBLE-ENDED IMPACT BIT
* 1 Bit – 2 Tip System, Square (Rob.) + Phillips
* Impact Rated, Color Coded Sizes
* Hardened Tips, Magnetic Ends
URCO410 RELAY OVERLOAD CAPACITOR
CAPACITOR, OVLD, RLY, 110 TO 125VAC, 115V

Designed for modern high efficiency compressors, easy mount clip for quick installation
For systems with or without run capacitors
Helps older compressors start and run cooler
Prevents low voltage starting problems
Wire designations - white/start, black/common, red/run
SF8426 TEE COPPER, 3/8" OD, SWAGED ONE SIDE X 1/4" MALE FLARE ON BRANCH - 2 EA
⅜" x 3" Tube, expanded to ⅜" ID on one side, ¼" Male Flare w/ Cap Wrench & Core

Features/Benefits

¼" SAE Male Flare
Brass cap with Neoprene O-ring
Stainless steel valve core, suitable for all refrigerants
A605 TAPERED T FITTING FOR MANOMETERS, 0.25"
With the TPI A605 Tapered T Fitting for Manometers, you can measure pressure with your compatible TPI manometer or combustion analyzer. The T fitting is tapered and measures 0.25" (6.35 mm).

Features

Compatible with TPI 610, 615, 620 and 625 manometers (sold separately)
For use when performing pressure measurements or setting pressure switches
LCR50X440 LB OVAL RUN CAPACITOR
CAPACITOR, RUN, OVAL, 50 MFD, 440V

10,000 AFC pressure sensitive short circuit interrupting capability
Continuous life tested, oil leak tested and dielectric tested for insulation effectiveness
Life tested to 85°C operating temperature for 10,000 cycles
Manufactured with thick polypropylene foil to handle increased operating temperatures, PCB-free oil to prevent over-heating
Meets EIA-456A accelerated life test at 70°C for 60,000 hours
US and Canada UL Approved (C22.2NO.190)


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.