TRADEFOX TFXJK FUSED MULTI JUMPER WITH SELECTOR SWITCHES
The Jumper King° allows you to quickly bypass any low voltage thermostat regardless of terminal style. This patent-pending all-in-one kit comes with everything you need to locate low-voltage shorts and eliminate compressor short cycling.

Features/Benefits

2-Spade Adapters, Jumper King° Thermostat Bypass Tool, Hard Carrying Case
6-Alligator Clips, 6-Magnetic Tips, 6-Jumper Leads, 6-Self Piercing Insulation Tips
For Use on low voltage circuits only (0-30VAC/VDC)
Four types of interchangeable tips: spade adapters, alligator clamps, magnetic tips and self-piercing insulation tips
Inovative selector switches to activate leads/circuits of your choosing at any time
No batteries required - powered by the low voltage in theA/C unit
Rugged unit has a rubberized boot, a magnet and fold-out hook for convenient mounting
Will never short out - contains a resettable popper fuse
Works on multiple stage units including heat pumps
41-409 HOT SURFACE FURNACE IGNITOR (CARBIDE) IG409
The Robertshaw® Carbide Series Hot Surface Ignitors deliver dependable ignition in heating systems of every description: furnaces, boilers, rooftop heaters, infrared burners, unit heaters, water heaters, and many other types of HVAC equipment.

Features and Benefits

Made from high-purity recrystallized silicon carbide. (Crystar™) which combines physical and thermal strength with stable electrical properties
Designed to reach ignition temperature(s) within 17 seconds
Have 18-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity
Manufactured with lead wires enclosed in a special high-temperature fiberglass insulation providing electrical protection
Operate at 120V AC. Some modules are rated for 208/240V input, however, the voltage to the ignitor is stepped down to 120V AC
39.90 38.00 38.0 CAD
A12-701 CONSTANT CUT-IN TEMPERATURE CONTROL
The Ranco® A12 and 9531 Series Constant Cut-in Temperature Controls are designed to switch electrical components of refrigeration systems in response to sensed temperatures.

Features and Benefits

Laser-welded stainless steel bellows
Fixed or adjustable temperature settings
High-amperage contacts
Pneumatic action provided by vapor-filled capillary or capillary with bulb sensing elements
Constant On or Off positions available
Choice of mounting brackets, adjustment ranges and cams, and slotted or flatted shafts
Standard 1/4” quick-connect terminals with optional screw terminals
BFT850DR ULTRA-LIGHTWEIGHT R-410A CLUTCH-TYPE ECCENTRIC FLARING TOOL WITH INTEGRATED POWER DRILL  OPERATION FEATURE AND RATCHET HANDLE
Dramatically reduces the time to make flares and has a tool used with a cordless drill for the fastest flaring.
HVAC BUBBLING LEAK FINDER DAUBER TYPE
• Glows Under Black Light, Enhancing Visibility
• High Viscosity Gas Leak Detection Fluid
• Clings To Vertical Surfaces, Freeze Proof to 0°F (-17.77°C)
• Fast, Accurate Detection Of The Smallest Leaks
• Convenient Dauber Type Applicator Cap
• Tiny leaks result in large bubbles and faster, larger
leaks are indicated by a stream of bubbles
CEL0255BS6EEA - 26,900 BTU/H 5F
UC C LP EL 4F 230 1PH M STD S 1
Evap. Temp : -20 °F Low Temp
Voltage : 208-230/1/60
1830-002 2CH & 2C INCINERATOR-TARGET PILOT UNI-KIT 5CH-6 90° LEFT HAND
The 1830 Series Pilot Uni-Kit® models are designed to be used with all Robertshaw® and most competitive thermocouples. Uni-Kit models include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type, model 2C.

Features and Benefits

Many flame pattern types available
Thermocouple or thermopile options
Spark electrode available
Horizontal or vertical gas inlet
Several mounting bracket types available
Aerated pilots with non-linting characteristics
SRL220 THERMOSTAT MANUAL RESET LIMIT THERMOSTAT
The SRL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

CSA approved
Manual Reset
UL® recognized

Terminals: Vertical ¼"
Cut out temp ( °F): 220 °F
Cut in temp ( °F): Manual
10.46 9.96 9.96 CAD
MBHP5E R-22, 404A, 410A GAUGES & 5' PREMIUM BV HOSES
This 2-valve manifold and gauge set has an anodized-aluminum block body with 1/4in SAE, 45° fittings and an extra access port in the center with a Schrader valve and hanging hook.
P70CA-1C PRESSURE CONTROL, SPST 20IN/100P
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
SSGSS3 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
P70LB-6C 20/80 PSIG LS 13 36 RANGE 100/425 PSIG HS; W/KNOB
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
URCO410 RELAY OVERLOAD CAPACITOR
CAPACITOR, OVLD, RLY, 110 TO 125VAC, 115V

Designed for modern high efficiency compressors, easy mount clip for quick installation
For systems with or without run capacitors
Helps older compressors start and run cooler
Prevents low voltage starting problems
Wire designations - white/start, black/common, red/run
URCO210 RELAY CAPACITOR OVERLOAD
CAPACITOR, OVLD, RLY, 110 TO 125VAC, 115V

Designed for modern high efficiency compressors, easy mount clip for quick installation
For systems with or without run capacitors
Helps older compressors start and run cooler
Prevents low voltage starting problems
Wire designations - white/start, black/common, red/run
P70CA-2C 50/450#, 1/4 MALE FLARE
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
SSGSS2 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
Q105 SEQUENCER
Q Series Sequencer, field proven for controlling the operation of heating elements and/or blower motors in electric, gas or oil heat systems. This sequencer has switches & turns on at 1-110 seconds, and off at 1-110 seconds.

Features/Benefits

24 volt control circuit
Five second delay between all subsequent stages, unless they function together
UL® and CSA® approved

Timing: Contacts M1-M2 will turn on 1st and turn off last
Off: 1 - 110 Seconds
On: 1 - 110 Seconds
26.83 25.55 25.55 CAD
DC710 COMBUSTION ANALYZER
Includes Carrying Case, Flue Probe and NIST Certification!
Operate remotely via Bluetooth using your Smartphone or tablet and the free TPI app. No need for long probe hoses – you can be at the control center with your smartphone, while the DC710 does the work at the stack.
The free TPI app provides on-site reports which can instantly be emailed and stored without the need for paper or printers.
24-Hour real-time clock for accurate documentation.
Powerful magnetic and/or hook mounting.
Durable, rugged and sealed housing.
OV42 OVERLOAD
OV Series 3 / 4" Universal Replacement Motor Protectors

Features/Benefits

Built in temperature activated disc opens and closes the motor overload protector's contacts
Protects compressor or motor from excessive high heat situations
UL® & CSA Approved
Universal replacement overload
Locked rotor amps: 27.0-31.0
hp @ 120 VAC: 1/6 thru 1/4
hp @ 240 VAC: 1/4+ thru 1
CCH0015MCACZ 1.5HP MED 3PH
CU CC SCRL 1.5HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/3/60
Application Capacity* : 17,540 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
8045-00 MECHANICAL DEFROST TIMER 120V AC TIME TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
DP60243 CONTACTOR 60A 24V 3 POLE
CONTACTOR, 3 PL, BX LUG, 75A, 24V, 60A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
CEL0060AS6AMA - 7,800 BTU/H 1F
UC C LP AIR IF 115 1PH M STD S 1
Evap. Temp : 25 °F Mid. Temp
Voltage : 115/1/60
P170AB-12C PRESSURE CONTROL, 12 IN. to 80 PSI, 1/4 IN. MALE FLARE CONN.
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
MO98 LUBRICATING OIL
Zoom Spout® Oiler is a paraffin base, non-gumming, high quality lubricating oil. Sold in a counter display case, each bottle has a flexible telescoping pull out spout to help access hard to reach areas.

Features/Benefits

All purpose lubricating oil
Flexible spout extends and retracts to any in-between length
Viscosity: 92-99 @ 140°F
Withstands high temperatures without breaking down
DP404803 CONTACTOR 40A 480V 3 POLE
CONTACTOR, 3 PL, BX LUG, 50A, 480V, 40A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
032F0181 SPARE PART KIT EVR(H)2-3 MU10/120
Service kit (NC); O-ring, (4) screws, armature assembly, rubber gasket, compression spring
BTC200R RATCHET TUBE CUTTER 1/8" TO 7/8"
This ratchet tube cutter features patented Set and Cut technology that provides easy tube cutting with little or no readjustment required.


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.