Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.

Can't find the part?
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
068U4900 THERM. EXP. VALVE KIT SMALL
TUA - Thermostatic Expansion Valves for Ice Machines
These kits are designed with contractors in mind to help save time and money by providing a universal valve that can easily be adapted to
replace most OEM specic TXVs. Two kits are available, each with a valve body and a selection of three orice sizes, copper ttings (two elbows
and one reducer), a patented bulb strap, and insulation tape.
1830-501 2CH & 2C INCINERATOR-TARGET PILOT UNI-KIT 2CHL-10
The 1830 Series Pilot Uni-Kit® models are designed to be used with all Robertshaw® and most competitive thermocouples. Uni-Kit models include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type, model 2C.

Features and Benefits

Many flame pattern types available
Thermocouple or thermopile options
Spark electrode available
Horizontal or vertical gas inlet
Several mounting bracket types available
Aerated pilots with non-linting characteristics
O10-1483 SINGLE LOW PRESSURE CONTROLS
The Ranco® O Series Single Low Pressure Controls offer a variety of pressure ranges and switch action to provide maximum application flexibility.

Features and Benefits

Controls available for most refrigerant types
High-amp rated switch (SPST) design (O10-1402/O10-1483)
Super Cap® capillary vibration protection system
Non-conductive front cover with captive screw
Adjustable differential and range
Easy-to-read scale plate
Vibration cone (absorbs and reduces vibration away from brazed joint)
Low mass copper alloy capillary tube (reduces capillary stress caused by equipment vibration)
The O16-624 control has additional features:

Compatible with refrigerants 134A, 401A, 401B, 402A, 402B, 403A, 403B and 404A
Cap included on all Australia temperature controls. Optional for all other regions
TCPVC PVC TUBE CUTTER
This heavy-duty, all-metal cutter is for CPVC, PVC and rubber tubing.
HP5E 5' (3-PK) PREMIUM STRAIGHT X BV ON END
This premium hose features all-weather flexibility and strength and comes in pack of 3 with a 5ft (150cm) measurement.
8145-20 MECHANICAL DEFROST TIMER 208-240V AC TIME / TEMPERATURE OR PRESSURE TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
RC15X450 MINISPLIT RUN CAP 15MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
068U4901 THERM. EXP. VALVE KIT LARGE
TUA - Thermostatic Expansion Valves for Ice Machines
These kits are designed with contractors in mind to help save time and money by providing a universal valve that can easily be adapted to
replace most OEM specic TXVs. Two kits are available, each with a valve body and a selection of three orice sizes, copper ttings (two elbows
and one reducer), a patented bulb strap, and insulation tape.
RC2.5X450 MINISPLIT RUN CAP 2.5MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
O10-1402 SINGLE LOW PRESSURE CONTROLS
The Ranco® O Series Single Low Pressure Controls offer a variety of pressure ranges and switch action to provide maximum application flexibility.

Features and Benefits

Controls available for most refrigerant types
High-amp rated switch (SPST) design (O10-1402/O10-1483)
Super Cap® capillary vibration protection system
Non-conductive front cover with captive screw
Adjustable differential and range
Easy-to-read scale plate
Vibration cone (absorbs and reduces vibration away from brazed joint)
Low mass copper alloy capillary tube (reduces capillary stress caused by equipment vibration)
The O16-624 control has additional features:

Compatible with refrigerants 134A, 401A, 401B, 402A, 402B, 403A, 403B and 404A
Cap included on all Australia temperature controls. Optional for all other regions
SSGSS5 SIGHT GLASS
Hermetically designed moisture indicator with 3% relative humidity sensitivity, intended for use on refrigerant lines.

Features/Benefits

3% relative humidity indication compared to 10% paper indicators
3% relative humidity sensitivity
Accurate color calibration at low ppm levels and higher temperatures
All brass corrosion resistant body
Fully hermetic design
Maximum working pressure: 680 psig
Single indicator for all common refrigerants
Solid copper fittings
Tri color coded: Blue/Purple/Pink
Wide angle viewing/ high visibility window for ease of monitoring
ETC-212000-000 ELECTRONIC TEMPERATURE CONTROL - TWO STAGE - 24V AC
The Ranco® ETC Series Electronic Temperature Control offers a full-featured electronic replacement for electrical-mechanical temperature controls used in many commercial refrigeration applications. With its wide temperature range, one and two stage capability, selectable heating/cooling modes and multi-voltage input, the ETC is designed to provide application flexibility. Models available include 120/208/240V AC and 24V AC.

Features and Benefits

Anti-short cycle compressor delay for cooling applications
Wide temperature range (-30°F to 220°F) (-34.4°C to 104.4°C)
Wide differential adjustment (1°F to 30°F) (-17°C to -1°C)
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps @ 120V AC and 8 Amps @ 208/240V AC) single stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings
8 foot lead with sensor is extendable up to 400 feet using 18 or 22-gauge thermostat wire
Easy 4-step set-up
Heavy-duty relay is 1 HP rated
Selectable °F or °C heating/cooling modes
Single and two stage models
NEMA 1 case and cover
NEMA 4X models available
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
DPAUX1 AUXILIARY SWITCH SPDT
Used to add additional load switching capability for other low load accessories that need to be controlled with the start/stop sequence of the equipment

Features/Benefits

For use with 3 Pole contactors ONLY
Provides easy connection points

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.