  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
AX36QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
BX66QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
AX52QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
BX64QP QUAD-POWER 4
Your team works tirelessly to ensure that every piece of machinery operates at peak efficiency, but interruptions due to retensioning result in costly downtime.
With Gates first maintenance-free premium V-belt, you're investing in a long-lasting solution that eliminates retensioning downtime and reduces replacement cycles, allowing your team to focus on the job without interruptions.
Featuring up to a 30% increase in power rating, Quad-Power 4 is engineered to offer next-gen torque capacity and optimize power transfer with unparalleled efficiency. The minimal-stretch cord technology of the belt reduces tension decay and delivers up to 200%* longer belt life and exceptional wear resistance, even in extreme temperatures.
Quad-Power 4 meets ARPM IP-3-3 and ISO 1813 static-conductivity standards, as well as ARPM IP-3-2 for oil and chemical-resistance standards.

RECOMMENDED FOR: high-horsepower and heavy-duty applications where durability and performance are crucial. These belts are commonly used in large facilities HVAC systems, agricultural equipment, food processing machinery and deep freeze warehouses, truck and bus accessory drives, and highway repair equipment.
FOR USE WITH: ARPM and ISO standard V-belt pulleys.
AB41090A 90° 5/16" SAE (1/2"-20 UNF) FM QC X 1/4" SAE M
This 1-piece MICRO-SEAL™ quick coupler hose adapter features 5/16in SAE female x 1/4in SAE male connectors with a straight design.
AB410A 5/16" SAE (1/2"-20 UNF) FM QC X 1/4" SAE M
This 1-piece MICRO-SEAL™ quick coupler hose adapter features 5/16in SAE female x 1/4in SAE male connectors with a straight design.
MO44 RUST BUSTER
BUSTER, RUST

Countertop display case
Flexible spout extends and retracts to any in-between length
Loosens rust in seconds
No lingering odor
034L0043 KVL 12 CRANKCASE PRES. REG. M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0052 KVL 35 CRANKCASE PRES. REG. M/7
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0147 KVC 15 HOT GAS BYPASS REG M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034N0082 CPCE 12 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034N0083 CPCE 15 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0045 KVL 22 CRANKCASE PRES. REG. M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0143 KVC 12 HOT GAS BYPASS REG M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0046 KVL 28 CRANKCASE PRES. REG. M/7
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034N0084 CPCE 22 HOT GAS BYPASS REG M/8
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
034L0144 KVC 22 HOT GAS BYPASS REG M/12
KVP/KVL/KVR/NRD/KVC/CPCE - Pressure Regulators
Danfoss has a variety of pressure regulators to control the low and
high pressure sides and efficient function of a refrigeration system
under varying load conditions.
Pressure regulators include:
• Evaporator Pressure Regulator (KVP)
• Crankcase Pressure Regulator (KVL)
• Condensing Pressure Regulator (KVR)
• Differential Pressure Regulator (NRD)
• Hot Gas Bypass Valves (KVC/CPCE)
TWD - BK112AF SAFETY GLASSES, GREY LENS, ANTI-FOG BLACK/GREY
Bearkat(R) Safety Glasses. Lens provide 99.9% UV protection. Bayonet temples. Duramass(R) scratch resistant coating. Meets the requirements of ANSI Z87.1+. CSA certified to Z94.3 standards. Black non-slip temple. Gray anti-fog lens tint and coating.
802 LINE VOLTAGE THERMOSTAT
The Robertshaw® 800 Series Line Voltage Thermostats are universal replacements for many other brands and can be used to retrofit most existing electric heat thermostats. With models for heating that include single-line break and double-line break as well as a single-line break cooling model, there is one for every application.

Features and Benefits

Convenient temperature display - View comfort level at-a-glance
Bimetal temperature sensing - For improved thermal performance
Mercury-free - No leveling or special disposal required
J-Box compatible - Not only will it meet code, but it speeds up installation
Positive-off switch - Assured shutdown of HVAC system
Universal replacement - Can retrofit most existing electric heat thermostats
HMA J-15 SINGLE-PIECE ROSEBUD HEATING TIP
Model HMA J-15 heating tip is a single-piece all copper tip tube and tip combination specifically designed for oxygen-acetylene heating applications. This tip has metal-to-metal contact seats. Thread sealants are not required when used with genuine Harris mixers. Conveniently vacuum-packed for point-of-purchase display.

Features
Single-piece tip-tube and rosebud tip combination
Copper construction
Specifically used for oxy-acetylene heating applications
Tip has metal-to-metal contact seats
Thread sealants not required when used with genuine Harris mixers
Marked with Harris logo and tip size for easy identification
One year warranty
Conveniently packaged for point-of-purchase display
183A/265 KIT DIGITAL MULTIMETER AND CLAMP-ON METER KIT
To use it's as simple as touching the plastic tip onto any connecting point or move it along an insulated wire. You will be notified if AC voltage is found by a sounded alarm and the plastic tip will glow a bright red. It will turn off at the next break in circuit or wire.

Features

Prevents electrical shocks
Measures: 50 to 1,000 VAC
No switch is required, always ready for use
Sound and bright red glow indicates voltage, buzzer will only react to AC voltage and not static electricity
UL listed
Lifetime Warranty
Applications

AC Voltage in Switches
AC Voltage in wall outlets
AC Voltage in junction boxes
BTC350 TUBE CUTTER 1/8" TO 1 5/8"
Features a lightweight aluminum forged body for brass, copper, and aluminum.
PHLIPBIT SQ1-PH1 GREEN/WHITE 4" DOUBLE-ENDED IMPACT BIT
PHLiPBiT™ solves the frustrating problem of driving or removing Square or Phillips screws on a common project. They combined the most popular tips & created a fully featured dual drive “Flip-&-Go” power bit.

1 Bit – 2 Tip System offers quick release convenience and industry leading benefits. Designed and strengthened with industrial grade tool steel, TruTorq hardened tips, precision recess contact, magnetic ends & torsion control zone. Impact rated heritage provides toughness, durability & maximum drive life with less strip out. Color coded body, laser etched ID markings. 1/4″ hex shank fits all impact drive machines and their Q/R Uni-Collet.

One PHLiPBiT replaces 2 singles, reduces inventory, saves time, money, produces frustration free, rapid load screw driving.
8045-00 MECHANICAL DEFROST TIMER 120V AC TIME TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
A12-1506 CONSTANT CUT-IN TEMPERATURE CONTROL
The Ranco® A12 and 9531 Series Constant Cut-in Temperature Controls are designed to switch electrical components of refrigeration systems in response to sensed temperatures.

Features and Benefits

Laser-welded stainless steel bellows
Fixed or adjustable temperature settings
High-amperage contacts
Pneumatic action provided by vapor-filled capillary or capillary with bulb sensing elements
Constant On or Off positions available
Choice of mounting brackets, adjustment ranges and cams, and slotted or flatted shafts
Standard 1/4” quick-connect terminals with optional screw terminals
8145-20 MECHANICAL DEFROST TIMER 208-240V AC TIME / TEMPERATURE OR PRESSURE TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
060L2150 KPU 19 THERMOSTAT 120 CAP TUBE SPDT M/10
KPU 19 - Thermostats
The KPU 19 thermostats are designed for easy installation and service with bottom and rear knockouts, differential adjustment dial,
a tamper-resistant design, and a robust thermoplastic housing.
O12-1549 LOW PRESSURE 10" TO 100 PSI MANUAL RESET, HIGH PRESSURE 150 TO 450 PSI MANUAL RESET
The Ranco® Dual Pressure Controls combine the functions of a single high-pressure limit control and a single low-pressure control in one unit with a single pole, single throw (SPST) switch.

Features and Benefits

Convertible feature allows selection of manual or reset function when operating at high pressure (O12‑4833/O12-4834)
A wide range of high-pressure manual or automatic reset controls can be replaced (O12-4833 or O12‑4834)
A high-pressure limit is combined with suction pressure sensing to provide temperature control and/or pump down
High-limit adjustment screw
Low-pressure differential and range adjusting screws
Selector screw for manual or automatic
Reset button
Low-pressure scale plate
High-impact plastic cover with center mount screw
High-pressure scale plate
Super Cap® capillary protection system
Color-coded for easy identification of pressure line
High-side capillary flare nut (silver)
Low-side capillary flare nut (brass)


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.