Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.



Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
41-402 HOT SURFACE FURNACE IGNITOR (CARBIDE)
The Robertshaw® Carbide Series Hot Surface Ignitors deliver dependable ignition in heating systems of every description: furnaces, boilers, rooftop heaters, infrared burners, unit heaters, water heaters, and many other types of HVAC equipment.

Features and Benefits

Made from high-purity recrystallized silicon carbide. (Crystar™) which combines physical and thermal strength with stable electrical properties
Designed to reach ignition temperature(s) within 17 seconds
Have 18-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity
Manufactured with lead wires enclosed in a special high-temperature fiberglass insulation providing electrical protection
Operate at 120V AC. Some modules are rated for 208/240V input, however, the voltage to the ignitor is stepped down to 120V AC
40.95 39.00 39.0 CAD
1309007-044 RANCO TEMPERATURE SENSOR | 2" LONG X 1/4" DIAMETER WITH 8' #22 AWG CABLE
The Ranco® ETC Series Electronic Temperature Control offers a full-featured electronic replacement for electrical-mechanical temperature controls used in many commercial refrigeration applications. With its wide temperature range, one and two stage capability, selectable heating/cooling modes and multi-voltage input, the ETC is designed to provide application flexibility. Models available include 120/208/240V AC and 24V AC.

Features and Benefits

Anti-short cycle compressor delay for cooling applications
Wide temperature range (-30°F to 220°F) (-34.4°C to 104.4°C)
Wide differential adjustment (1°F to 30°F) (-17°C to -1°C)
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps @ 120V AC and 8 Amps @ 208/240V AC) single stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings
8 foot lead with sensor is extendable up to 400 feet using 18- or 22-gauge thermostat wire
Easy 4-step set-up
Heavy-duty relay is 1HP rated
Selectable °F or °C heating/cooling modes
Single and two stage models
NEMA 1 case and cover
NEMA 4X models available
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
SHL507 PLENUM THERMOSTAT
The SHL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

36T Electrical Ratings
CSA approved
Direct OEM replacements
Economical
L140-30 SPST
UL® recognized
CCH0030LCBCZ 3.0HP LOW 3PH
CU CC SCRL 3.0HP 208-230/3/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/3/60
Application Capacity* : 13,200 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.15
SLS150 THERMOSTAT AUTO RESET LIMIT THERMOSTAT
The SLS series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

Auto and manual reset
CSA approved
UL® recognized


Terminals: 45° angle ¼"
Cut out temp ( °F): 150 °F
Cut in temp ( °F): 110 °F
Differential °: 40 °F
9.19 8.75 8.75 CAD
709 COMBUSTION EFFICIENCY ANALYZER WITH DIFFERENTIAL MANOMETER
The TPI 709 Flue Gas Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion.
All the features of the 708 PLUS high resolution 0.001 in H20 differential manometer for high efficiency and oil equipment
Calculates combustion efficiency
Pump driven for fast response
Will not shut off if 15 ppm CO is present for increased safety
Optional A740 IR printer available for hard copies of test results
Built-in differential thermometer
Store function to save up to 50 readings
Push on fittings for fast and easy use
Large easy to read backlit display
Ten selectable fuels
RC2X450 MINISPLIT RUN CAP 2MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
CCH0055MCACZ 5.5HP MED 3PH
CU CC SCRL 5.5HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25.0 °F
Voltage : 208-230/3/60
Application Capacity* : 42,200 BTU/H
Refrigerant Type : R448A
AWEF Value : 7.6"
T1048 SPADE - INS (20PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG #10 stud 13/64" I.D. 20 Pieces
RS9110T SINGLE-STAGE 1 HEAT / 1 COOL PROGRAMMABLE TOUCHSCREEN THERMOSTAT
RS9000 Pro-Series Programmable Touchscreen Wall Thermostat
Contractors can offer owners easy, yet powerful and reliable single-stage heating and cooling control in a simple, modern design with the RS9110T programmable Touchscreen wall thermostat.
Single Stage - 1 Heat / 1 Cool

• Large terminal blocks for easy installation
• Universal sub-base
• Quick-access menu button
• Contractor/technician setup menu
• Easy-to-understand programming menus
• Intuitive wake, leave, return, sleep programming icons
• 24V AC Powered OR Battery Operation (Included)
• 6Year Limited Warranty
• Factory pre-set energy efficiency program
Simple, yet powerful control.
• Large, easy-to-read 8.8-square-inch blue backlit touchscreen display
• Easy-access front-load battery compartment
• Adjustable temperature differential (swing) for energy optimization and maximum
• Auto changeover
• Five-minute selectable on/off compressor delay protection for short-cycling prevention
• Minimum compressor run time
• Filter change reminder
• Keypad lockout
126.00 120.00 120.0 CAD
41-414 HOT SURFACE FURNACE IGNITOR (CARBIDE) IG414
The Robertshaw® Carbide Series Hot Surface Ignitors deliver dependable ignition in heating systems of every description: furnaces, boilers, rooftop heaters, infrared burners, unit heaters, water heaters, and many other types of HVAC equipment. Packaging includes special mounting adaptors.

Features and Benefits

Made from high-purity recrystallized silicon carbide. (Crystar™) which combines physical and thermal strength with stable electrical properties
Designed to reach ignition temperature(s) within 17 seconds
Have 18-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity
Manufactured with lead wires enclosed in a special high-temperature fiberglass insulation providing electrical protection
Operate at 120V AC. Some modules are rated for 208/240V input, however, the voltage to the ignitor is stepped down to 120V AC
42.00 40.00 40.0 CAD
ROBERTSHAW RS8110 SINGLE-STAGE 1 HEAT / 1 COOL NON-PROGRAMMABLE THERMOSTAT
RS8000 Pro-Series Non-Programmable Wall Thermostat
Contractors can offer owners easy, yet powerful and reliable single-stage heating and cooling control in a simple, modern design with the RS8110 non-programmable wall thermostat.
Single Stage - 1 Heat / 1 Cool

• Large terminal blocks for easy installation
• Universal sub-base
• Quick-access menu button
• Contractor/technician setup menu
• Large, easy-to-read 4.6-square-inch blue backlit display
• 24V AC Powered OR Battery Operation (Included)
• 6Year Limited Warranty
• Easy-access front-load battery compartment
• Adjustable temperature differential (swing) for energy optimization and maximum system life
• Adjustable room temperature calibration
• Adjustable setpoint limits
• Five-minute selectable on/off compressor delay protection for short-cycling prevention
• Separate O and B terminals
SFC300400 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
CS108-130X110 START CAPACITOR
CAPACITOR,START,108 – 130 MFD,110V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-7/16 in
SFC275350 FAN CYCLE PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45L female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Will not replace solenoids with internal metering orifices
CCH0035LBACZ 3.5HP LOW 1PH
CU CC SCRL 3.5HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10.0 °F
Voltage : 208-230/1/60
Application Capacity* : 14,040 BTU/H
Refrigerant Type : R448A
AWEF Value : 3.15
TLMKC18 SOLENOID VALVE TROUBLESHOOTING MAGNET, 18MM
This solenoid valve troubleshooting magnet is a must-have tool that manually opens solenoid valves by lifting its stem and plunger using an industrial-grade magnet housed inside of durable ABS plastic.
RC20X450 MINISPLIT RUN CAP 20MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
SHL514 PLENUM THERMOSTAT
The SHL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

36T Electrical Ratings
CSA approved
Direct OEM replacements
Economical
L180-40 SPST
UL® recognized
8145-00 MECHANICAL DEFROST TIMER 120V AC TIME / TEMPERATURE OR PRESSURE TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
SHL502 GAS FURNACE LIMIT THERMOSTAT
The SHL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

36T Electrical Ratings
CSA approved
Direct OEM replacements
Economical
L180-30 SPST
UL® recognized
24.15 23.00 23.0 CAD
DP751203 CONTACTOR 75A 120V 3 POLE
CONTACTOR, 3 PL, BX LUG, 90A, 120V, 75A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
OV46 OVERLOAD
OV Series 3 / 4" Universal Replacement Motor Protectors

Features/Benefits

Built in temperature activated disc opens and closes the motor overload protector's contacts
Protects compressor or motor from excessive high heat situations
UL® & CSA Approved
Universal replacement overload
Locked rotor amps: 36.0-40.0
hp @ 120 VAC: 1/4 thru 1/2
hp @ 240 VAC: 1/2+ thru 1
10-6830 FLAME SENSOR GOODMAN DIRECT REPLACEMENT WITH A STRAIGHT ROD
680 Series
Enhance the performance and safety of your HVAC system with the Robertshaw® Goodman Direct Replacement Flame Sensor with a Straight Rod.

Designed as an exact match for Goodman's 0130F00010S.

Will fit in a variety of Goodman and Amana Furnace series, ADV, AMV, CPG, DBG, DC80, DC96, DCG, DD80, DFG, DK92, DM80, DM92S, DM96, DRG, DSG, GC9, GCE, GCH, GM9, GME, GMS, GMV, GPD, GPG.
CS189-227X330 START CAPACITOR
CAPACITOR, START, 189 – 227 MFD, 330V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 2-9/16 in
TLMIR2 TECH-SET™ CIRCULAR TELESCOPING MIRROR 57MM DIAMETER
This telescoping mirror is suitable for fast, accurate inspection of any hidden area. The universal ball joints hold the mirror firmly at any desired angle.
CS400-480X110 START CAPACITOR
CAPACITOR, START, 400 – 480 MFD, 110V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-13/16 in
RC1X450 MINISPLIT RUN CAP 1MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.