Subscribe for Updates

Get promotions, product news and HVAC-R insights directly to your inbox.



Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
Logo STAY TUNED! MORE LOCATIONS COMING SOON!!!
  • Air Filters
  • Chemicals, Lubricants
  • Controls
  • Electrical Components
  • Fans, Blowers, Belts, Bearings, Pulleys
  • Pipe, Tubing, Fittings, Insulation
  • Refrigeration Equipment
  • Tools & Instruments
  • Walk-In Cooler Installation Materials
  • Water Pumps
  • Welding
S903758 IGNITER KIT
Supco® igniters offer an efficient , stronger, reliable hot surface Silicon Carbide design.

Features/Benefits

18 gauge copper high temperature fiberglass insulated lead wires
Exact replacement hot surface igniters
Faster time to temperature response
Lower power consumption
Stronger more durable design
Superior gas lighting ability
31.50 30.00 30.0 CAD
SHL505 PLENUM THERMOSTAT
The SHL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

36T Electrical Ratings
CSA approved
Direct OEM replacements
Economical
L140-40 SPST
CCH0022LBBCZ 2.0HP LOW 1PH
CU CC SCRL 2.0HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/1/60
Application Capacity* : 9,310 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.09
P70CA-1C PRESSURE CONTROL, SPST 20IN/100P
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
CCH0015MCACZ 1.5HP MED 3PH
CU CC SCRL 1.5HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/3/60
Application Capacity* : 17,540 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
8045-00 MECHANICAL DEFROST TIMER 120V AC TIME TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
DP404803 CONTACTOR 40A 480V 3 POLE
CONTACTOR, 3 PL, BX LUG, 50A, 480V, 40A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
MAP-PRO™ HAND TORCH REPLACEMENT CYLINDER 14.1 OZ.
MAP-Pro™ 14.1 oz. hand torch cylinder contains premium fuel suited for a variety of job site projects. MAP-Pro works faster and more efficiently with a higher burn temperature than standard propane. This tank works well with Harris' air-fuel hand torches.

Features
Provides maximum heat output and transfer for more efficient use
Faster soldering times than Harris' propane cylinders
Flame temperature in air of 3730 degrees F (2054 degrees C)
Constructed of durable steel
Slim and lightweight cylinder is easy to grip and maneuver
250 PSI operating pressure
Use with Harris air-fuel hand torches
One year warranty
WC-Y-25R STANDARD YELLOW WIRE CONNECTOR WITH - 25 EA
Easy-Twist wire connectors are the professional choice for forming quick, secure connections between wires in the field. The specialized spring design grips in fewer twists and the outside of the connector is ribbed to offer a comfortable grip.

[Conical Spring] The fixed zinc-plated square spring has a precise conical shape that grips in fewer turns and can dead end a single wire
[Ergonomic Grip] Entire connector features a ribbed texture for easier twisting and a more secure gripping surface to increase your productivity
[Thermoplastic Shell] NSI connectors have a flame-retardant UL 94V-2 thermoplastic body that delivers durable performance and electrical insulation
[Compact Design] Easy to install in tight areas; the extra-thick cap, deep-skirt entry and threaded funnel make these connectors more reliable and protect against flashover and shorts
[Labor Saving] Save time and effort with professional-quality connectors that install in half the time of a typical wire connector and don’t require pre-twisting of wires
Q104 SEQUENCER
Q Series Sequencer, field proven for controlling the operation of heating elements and/or blower motors in electric, gas or oil heat systems. This sequencer has 2 switches & turns on at 30-90 seconds, and off at 1-30 seconds.

Features/Benefits

24 volt control circuit
Five second delay between all subsequent stages, unless they function together
UL® and CSA® approved

Off: 1 - 30 Seconds
On: 30 - 90 Seconds
17.24 16.42 16.42 CAD
OATEY® MEDIUM CLEAR PVC CEMENT CAN 118ML
Oatey® PVC Medium Bodied Fast Set Clear Cement is recommended for potable water, pressure pipe, conduit and DWV applications. It can be used on all schedules and classes of PVC pipe and fittings up to 6 in. diameter with interference fit. Oatey products have earned the trust of plumbing professionals for over 100 years.
SF3810 VALVE CORE WRENCH, 5LB TORQUE
Pre-set to 5 inch-pounds torque, non-adjustable.

Features/Benefits

Pre-set to 5 inch-pounds (non-adjustable)
060L2151 KPU 19 THERMOSTAT 80 CAP TUBE SPST M/10
KPU 19 - Thermostats
The KPU 19 thermostats are designed for easy installation and service with bottom and rear knockouts, differential adjustment dial,
a tamper-resistant design, and a robust thermoplastic housing.
P70AB-12C SPST PRESSURE CONTROL; 12"/80# 1/4"FLARE 36" CAP
The P70 and P170 Controls for low pressure applications are designed primarily for low pressure cut-out control, pump-down control, and capacity control on commercial refrigeration and air conditioning applications.
CCH0045LBBCZ 4.5HP LOW 1PH
CU CC SCRL 4.5HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10.0 °F
Voltage : 208-230/1/60
Application Capacity* : 17,140 BTU/H
Refrigerant Type : R448A
AWEF Value : 3.15
SFC200240 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
CS378-440X110 START CAPACITOR
CAPACITOR,START,378 – 440 MFD,110V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-13/16 in
IM2 INSPECTION MIRROR 1 X 2 OVAL
Telescoping tools match clip, magnet and inspection mirrors

Features/Benefits

1" x 2" oval glass mirror
Carry pouch included
Double ball joint head adjustment
Extendable/retractable design
Glass mirrors
Magnified glass mirror available with IM6
Pocket clip
P70DA-1C 50/450# M/R OPEN-HI 36",# SW.
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
X3596 5 EXTRA DIAL PIN FOR PARAGON 208-240V DEFROST TIMER
The Paragon® 9045-00 and 9145-00 Universal Defrost Timers (UDT) are the only multi-voltage defrost timers engineered to industry refrigeration standards. Designed to withstand the most rigorous refrigeration applications, this control offers a real-time clock and 100 hours of power loss protection for both time and defrost schedules. Mechanism-only models also are available to fit in standard defrost timer enclosures.

Features and Benefits

Certified to UL873 standard for temperature-indicating and regulating equipment
Wires directly to 120V AC, 208V AC or 240V AC power sources without jumpers or switches
Rated to 30,000 cycles for refrigeration controllers with switches
Easy programming, easy set-up, set time, set defrost start and defrost end
Initiate 15 minute manual defrost
100 hours of power loss protection for both time and defrost schedule
Real-time clock
Lighted display shows defrost start time and duration
System status indicators
DP601203 CONTACTOR 60A 120V 3 POLE
CONTACTOR, 3 PL, BX LUG, 75A, 120V, 60A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
ROBERTSHAW RS8210 MULTI-STAGE 2 HEAT / 1 COOL NON-PROGRAMMABLE THERMOSTAT
RS8000 Pro-Series Non-Programmable Wall Thermostat
Contractors can offer owners easy, yet powerful and reliable two-stage heating and one-stage cooling control in a simple, modern design with the RS8210 non-programmable wall thermostat.
Multi-Stage - 2 Heat / 1 Cool

• Large terminal blocks for easy installation
• Universal sub-base
• Quick access menu button
• Contractor/technician setup menu Simple, yet powerful control.
• Large, easy-to-read 4.6-square-inch blue backlit display
• 24V AC Powered OR Battery Operation (Included)
• 6Year Limited Warranty
• Easy-access front-load battery compartment
• Adjustable temperature differential (swing) for energy optimization and maximum system life
• Adjustable room temperature calibration
• Adjustable setpoint limits
• Filter change reminder
• Five-minute selectable on/off compressor delay protection for short-cycling prevention
• Separate O and B terminals
CCH0030MCACZ 3.0HP MED 3PH
CU CC SCRL 3.0HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25 °F
Voltage : 208-230/3/60
Application Capacity* : 31,930 BTU/H
Refrigerant Type : R404A
AWEF Value : 7.6
T1006 QUICK DISC - INSULATED (10PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG ¼" (.250") Male Fully Insulated 10 Pieces
CS145-175X110 START CAPACITOR
CAPACITOR, START, 145 – 175 MFD, 110V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-7/16 in
OV40 OVERLOAD
OV Series 3 / 4" Universal Replacement Motor Protectors

Features/Benefits

Built in temperature activated disc opens and closes the motor overload protector's contacts
Protects compressor or motor from excessive high heat situations
UL® & CSA Approved
Universal replacement overload
Locked rotor amps: 22.5-26.5
hp @ 120 VAC: 1/6 thru 1/4
hp @ 240 VAC: 1/4 thru 1
RC12.5X450 MINISPLIT RUN CAP 12.5MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
SFC200365 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.