CCH0030LBACZ 3.0HP LOW 1PH
CU CC SCRL 3.0HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/1/60
Application Capacity* : 13,200 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.15
SFC150225 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
SF3800 VALVE CORE CONTAINER, WRENCH, THREAD CHASER AND (6) CORES
Two tools in one, a core wrench and thread chaser, complete with a core carrying case and six cores.

Features/Benefits

Carrying case can hold several additional cores if desired
Multi-use tool acts as cap for carrying case
ETC-212000-000 ELECTRONIC TEMPERATURE CONTROL - TWO STAGE - 24V AC
The Ranco® ETC Series Electronic Temperature Control offers a full-featured electronic replacement for electrical-mechanical temperature controls used in many commercial refrigeration applications. With its wide temperature range, one and two stage capability, selectable heating/cooling modes and multi-voltage input, the ETC is designed to provide application flexibility. Models available include 120/208/240V AC and 24V AC.

Features and Benefits

Anti-short cycle compressor delay for cooling applications
Wide temperature range (-30°F to 220°F) (-34.4°C to 104.4°C)
Wide differential adjustment (1°F to 30°F) (-17°C to -1°C)
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps @ 120V AC and 8 Amps @ 208/240V AC) single stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings
8 foot lead with sensor is extendable up to 400 feet using 18 or 22-gauge thermostat wire
Easy 4-step set-up
Heavy-duty relay is 1 HP rated
Selectable °F or °C heating/cooling modes
Single and two stage models
NEMA 1 case and cover
NEMA 4X models available
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
SF2000 CONNECTOR, 1/4 FEMALE SWIVEL
¼" Male Flare X ¼" Female Flare Knurled Swivel w/ Depressor Tip & seal

Features/Benefits

¼" Female Knurled Swivel
¼" SAE Male Flare
Depressor Tip and Seal
T1003 QUICK DISC - INSULATED (20PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG ¼" (.250") Male Tab 20 Pieces
TD69 TIME DELAY
Time Delay on Make Timers (DOM)

Features/Benefits

1/4" male quick connect terminals
Adjustable time delay on make 6 seconds to 8 minutes
Cut the jumper wire to use in 110/250 volts
Delay on Make Timer (DOM)
SFC110170 FAN CYCLING PRESSURE SWITCH
Fan cycling low pressure switches

Features/Benefits

¼" SAE 45° female flare fitting with valve core depressor
Condenser fan cycling switch closes on pressure rise
Automatic Reset
Life at rated load: 100,000 cycles
Rated Voltage 24/120/240 VAC @ 50/60 Hz
Small size and light weight for direct mounting
Snap acting stainless steel hermetically sealed sensor
Wire is 18 AWG, 18" long
OV48 OVERLOAD
OV Series 3 / 4" Universal Replacement Motor Protectors

Features/Benefits

Built in temperature activated disc opens and closes the motor overload protector's contacts
Protects compressor or motor from excessive high heat situations
UL® & CSA Approved
Universal replacement overload
WARNING: Prop 65 info

Locked rotor amps: 40.5-44.5
hp @ 120 VAC: 1/3 thru 3/4
hp @ 240 VAC: 1/2+ thru 1
DPAUX1 AUXILIARY SWITCH SPDT
Used to add additional load switching capability for other low load accessories that need to be controlled with the start/stop sequence of the equipment

Features/Benefits

For use with 3 Pole contactors ONLY
Provides easy connection points
IM5 INSP MIRROR 2.25 X 3.25 RECT
Telescoping tools match clip, magnet and inspection mirrors

Features/Benefits

2 ¼" x 3 ¼" rectangular glass mirror
Carry pouch included
Double ball joint head adjustment
Extendable/retractable design
Glass mirrors
Magnified glass mirror available with IM9
Vinyl grip handle
DP50243 CONTACTOR 50A 24V 3 POLE
CONTACTOR, 3 PL, BX LUG, 65A, 24V, 50A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration
CCH0045LCBCZ 4.5HP LOW 3PH
CU CC SCRL 4.5HP 208-230/3/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10.0 °F
Voltage : 208-230/3/60
Application Capacity* : 17,140 BTU/H
Refrigerant Type : R448A
AWEF Value : 3.15
CS145-175X330 START CAPACITOR
CAPACITOR,START,145 – 175 MFD,330V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 2-9/16 in
T1005 QUICK DISC - INSULATED (10PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG ¼" (.250") Female Fully Insulated 10 Pieces
CCH0035MCACZ 3.5HP MED 3PH
CU CC SCRL 3.5HP 208-230/3/60 MED
Ambient Temp : 95 °F
Suction Temp : 25.0 °F
Voltage : 208-230/3/60
Application Capacity* : 32,610 BTU/H
Refrigerant Type : R448A
AWEF Value : 7.6
P70AA-118C 100/400# DIFF. ADJ.; 35/200# 36CAP; 13
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
CCH0018LBBCZ 1.8HP LOW 1PH
CU CC SCRL 1.8HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/1/60
Application Capacity* : 8,290 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.05
FLS301 FLAME SENSOR
SUPCO® flame sensors can replace many of the popular sensors in today's furnaces that use hot surface or direct spark ignition systems.

Features/Benefits

Alumina ceramic insulator
For Hot Surface Ignition (HSI) systems
Kanthal flame rod material can withstand 1800°F
Mount on multiple burners, or adjacent to igniter
Use with spark ignition and flame sensing

Sensor Angle: 90° Offset
Length (Flange to Tip): 2.5"
Termination: .25" Quick Disconnect
TD68 TIME DELAY
Time Delay on Make Timers (DOM)

Features/Benefits

1/4" male quick connect terminals
Adjustable time delay on make relay 6 seconds to 8 minutes
Cannot be used with a cooling anticipator
Delay on Make Timers (DOM)
LUBRICANT FOR O-RINGS 1000Cst 4OZ
Product Features
High viscosity 1000 cSt Silicone O-ring Lubricant helps hold parts in place when rebuilding compressors.
Lubricants helps to Extend O-ring Life.
Resists wash-away & moisture.
Withstands high temperatures.
Easy to apply, comes in convenient 4 oz. squeeze tip bottle.
CS108-130X330 START CAPACITOR
CAPACITOR,START,108 – 130 MFD,330V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 2-1/16 in
SM5411 9 WATT COND MOTOR 120V CWLE
For commercial and domestic refrigeration equipment, room and hood ventilators, evaporative coolers and various other equipment.

Features/Benefits

50/60Hz
Cast aluminum housing up to 16 watts
Hardware included
Overload protected
Permanent lubrication
Rotation determined by viewing opposite shaft end
Single rotation
Single speed, 1550 RPM
Sleeve bearings
Threaded mounting holes
Totally enclosed
UL® Approved
Universal mounting
RS9055OUT WIRELESS OUTDOOR TEMPERATURE SENSOR
The Robertshaw RS9055OUT Wireless Outdoor Temperature Sensor for dual fuel heat pump balance point applications, seamlessly connects to your wall thermostat to optimize comfort and energy efficiency by monitoring indoor and outdoor temperatures for precise heating control.

• Senses outdoor temperature
• Use for dual fuel heat pumps balance point applications
• Durable weatherproof design
• Compatible with RS9423T or RS10421T thermostat
• Wireless range from sensor to thermostat is 328 feet (100m)
• Battery powered (Battery included)
• 6 year limited warranty
T1124 CONNECTOR (10PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

¼" (.250") Female QC X #6 Screw 10 Pieces
CCH0010LCBCZ 1.0HP LOW 3PH
CU CC SCRL 1.0HP 208-230/3/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/3/60
Application Capacity* : 6,310 BTU/H
Refrigerant Type : R404A
AWEF Value : 2.97
FSC10 FLAME SENSOR CLEANER
Handy flame sensor cleaner useful in any service technician's tool kit.

Features/Benefits

Convenient key ring
Easily clean sensors
Prevents false starts
RS9110 SINGLE-STAGE 1 HEAT / 1 COOL PROGRAMMABLE THERMOSTAT
RS9000 Pro-Series Programmable Wall Thermostat
Contractors can offer owners easy, yet powerful and reliable single-stage heating and cooling control in a simple, modern design with the RS9110 programmable wall thermostat.
Single Stage - 1 Heat / 1 Cool

• Large terminal blocks for easy installation
• Universal sub-base
• Quick-access menu button
• Contractor/technician setup menu
• Easy-to-understand programming menus
• Intuitive wake, leave, return, sleep programming icons
• 24V AC Powered OR Battery Operation (Included)
• 6Year Limited Warranty
• Factory pre-set energy efficiency program Simple, yet powerful control.
• Large, easy-to-read 4.6-square-inch blue backlit display
• Easy-access front-load battery compartment
• Adjustable temperature differential (swing) for energy optimization and maximum system life
• Adjustable room temperature calibration
• Adjustable setpoint limits
• Five-minute selectable on/off compressor delay protection for short-cycling prevention
• Separate O and B terminals
• Filter change reminder

WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…
    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.