T1039 RINGS - INSULATED (15PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG ⅜" stud 25/64" I.D. 15 Pieces
Q105 SEQUENCER
Q Series Sequencer, field proven for controlling the operation of heating elements and/or blower motors in electric, gas or oil heat systems. This sequencer has switches & turns on at 1-110 seconds, and off at 1-110 seconds.

Features/Benefits

24 volt control circuit
Five second delay between all subsequent stages, unless they function together
UL® and CSA® approved

Timing: Contacts M1-M2 will turn on 1st and turn off last
Off: 1 - 110 Seconds
On: 1 - 110 Seconds
26.83 25.55 25.55 CAD
SF3800 VALVE CORE CONTAINER, WRENCH, THREAD CHASER AND (6) CORES
Two tools in one, a core wrench and thread chaser, complete with a core carrying case and six cores.

Features/Benefits

Carrying case can hold several additional cores if desired
Multi-use tool acts as cap for carrying case
T1150 WIRE CONNECTOR (20PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

Small blue wire connector with spring insert (20 Pcs)
T1005 QUICK DISC - INSULATED (10PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG ¼" (.250") Female Fully Insulated 10 Pieces
FLS301 FLAME SENSOR
SUPCO® flame sensors can replace many of the popular sensors in today's furnaces that use hot surface or direct spark ignition systems.

Features/Benefits

Alumina ceramic insulator
For Hot Surface Ignition (HSI) systems
Kanthal flame rod material can withstand 1800°F
Mount on multiple burners, or adjacent to igniter
Use with spark ignition and flame sensing

Sensor Angle: 90° Offset
Length (Flange to Tip): 2.5"
Termination: .25" Quick Disconnect
FSC10 FLAME SENSOR CLEANER
Handy flame sensor cleaner useful in any service technician's tool kit.

Features/Benefits

Convenient key ring
Easily clean sensors
Prevents false starts
P70LB-1C SINGLE POLE DUAL PRESS, SPST, 20" WE TO 100 PSI LOW PRESS.100 PSI TO 500 PSI HIG
The P70 and P170 Controls for high pressure applications are designed primarily for high pressure cut-out control, head-pressure control, and condenser fan cycling control on commercial refrigeration and air conditioning applications.
SHL140 THERMOSTAT LIMIT CONTROL
he SHL Series of 3/4" (19mm) bimetal disc temperature controls offers proven reliability in a versatile, cost-effective design. Can handle loads up to 25 amps at 240VAC.

Features/Benefits

Available with automatic and manual reset SPST or automatic reset SPDT switch configurations.
CSA approved
Limit - open on rise
UL® recognized
Welded construction for integrity of current-carrying components.
9.20 8.76 8.76 CAD
RC3X450 MINISPLIT RUN CAP 3MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
SIG101 FURNACE IGNITER
Exact replacement silicon carbide round igniter

Features/Benefits

18 gauge copper high temperature fiberglass insulated lead wires
Exact replacement hot surface igniters
Faster time to temperature response
Higher resistance to oxidation
Longer usable life
Lower power consumption
More robust in transit
Stronger more durable design
Supco® round igniters offer an efficient , stronger, reliable hot surface Silicon Carbide design
Superior gas lighting ability
31.40 29.90 29.900000000000002 CAD
OV48 OVERLOAD
OV Series 3 / 4" Universal Replacement Motor Protectors

Features/Benefits

Built in temperature activated disc opens and closes the motor overload protector's contacts
Protects compressor or motor from excessive high heat situations
UL® & CSA Approved
Universal replacement overload
WARNING: Prop 65 info

Locked rotor amps: 40.5-44.5
hp @ 120 VAC: 1/3 thru 3/4
hp @ 240 VAC: 1/2+ thru 1
ZFD25KVE-TFE-261 COPELAND SCROLL DIGITAL REFRIGERATION COMPRESSOR
The Copeland Scroll Digital Refrigeration compressor family is designed for superior efficiency and performance for low temperature applications.
TFXUPL UNIVERSAL PIPE LEVEL
This technician invented clamp level takes the headache out of balancing levels on copper pipe or PVC. Just clamp it on & level up your HVAC and Plumbing game.

Features/Benefits

Level pipe sizes from 3/8" to 2"
Clamp firmly attaches to pipe for hands free leveling
Made of durable ABS plastic
Part of our SUPCO® TradeFox™ Technician-Invented product line
8045-20 MECHANICAL DEFROST TIMER 208/240V AC TIME TERMINATION
The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

Features and Benefits

Time initiated; temperature, pressure or time terminated models available
High-amp switch contacts: 40 Amps, 2 HP
Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
Safety back-up - mechanical time-driven defrost termination
Heavy-duty synchronous design drive motor
Choice of three contact arrangements
Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock
All 8240 models have an adjustable cut-in pressure dial calibrated from 36-110 pounds for R12, R22, R502
ETC-211000-000 ELECTRONIC TEMPERATURE CONTROL - TWO STAGE - 120/208/240V AC
The Ranco® ETC Series Electronic Temperature Control offers a full-featured electronic replacement for electrical-mechanical temperature controls used in many commercial refrigeration applications. With its wide temperature range, one and two stage capability, selectable heating/cooling modes and multi-voltage input, the ETC is designed to provide application flexibility. Models available include 120/208/240V AC and 24V AC.

Features and Benefits

Anti-short cycle compressor delay for cooling applications
Wide temperature range (-30°F to 220°F) (-34.4°C to 104.4°C)
Wide differential adjustment (1°F to 30°F) (-17°C to -1°C)
LCD read-out for sensor temperature, control settings, and relay status
High Amp output relay (FLA 16 Amps @ 120V AC and 8 Amps @ 208/240V AC) single stage
EEPROM memory retains control settings during power outages
Keypad lockout to prevent end-user alteration of settings
8 foot lead with sensor is extendable up to 400 feet using 18 or 22-gauge thermostat wire
Easy 4-step set-up
Heavy-duty relay is 1 HP rated
Selectable °F or °C heating/cooling modes
Single and two stage models
NEMA 1 case and cover
NEMA 4X models available
White backlight on display
Sensor rated IP67 for dust and water (<1m) resistance
CS161-193X165 START CAPACITOR
CAPACITOR,START,161 – 193 MFD,165V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-7/16 in
CCH0030LBACZ 3.0HP LOW 1PH
CU CC SCRL 3.0HP 208-230/1/60 LOW
Ambient Temp : 95 °F
Suction Temp : -10 °F
Voltage : 208-230/1/60
Application Capacity* : 13,200 BTU/H
Refrigerant Type : R404A
AWEF Value : 3.15
RC10X450 MINISPLIT RUN CAP 10MFD 450V
Run capacitors for use in Mini Split applications.

Features/Benefits

Meets IEC 252 Standard
Plastic construction
Quad blade quick connect terminals
UL recognized
FLS013 FLAME SENSOR
SUPCO® flame sensors can replace many of the popular sensors in today's furnaces that use hot surface or direct spark ignition systems.

Features/Benefits

Alumina ceramic insulator
For Hot Surface Ignition (HSI) systems
Kanthal flame rod material can withstand 1800°F
Mount on multiple burners, or adjacent to igniter
Use with spark ignition and flame sensing
SHL516 PLENUM THERMOSTAT
The SHL series of 1/2" bimetal temperature controls offers proven reliability in a compact, versatile, cost-effective design.

Features/Benefits

36T Electrical Ratings
CSA approved
Direct OEM replacements
Economical
L210-40 SPST
UL® recognized
TLMIR3 TECH-SET™ RECTANGULAR TELESCOPING MIRROR 89 X 54MM
This rectangular telescoping mirror is suitable for fast, accurate inspection of any hidden area. The universal ball joints hold the mirror firmly at any desired angle.
T1057 CLOSED END CONNECTOR (15PC)
Supco® terminal service packs are handy and low priced, ideal for small jobs.

Features/Benefits

16-14 AWG insulated crimp type 15 Pieces
DP401202 CONTACTOR 40A 120V 2 POLE
CONTACTOR, 2 PL, BX LUG, 50A, 120V, 40A

Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
CCH0045LEBCZ 4.5HP MED 3PH 575V
CU SCRL 4.5HP 575/3/60 MED
Ambient Temp : 95 °F
Suction Temp : -10.0 °F
Voltage : 575/3/60
Application Capacity* : 17,140 BTU/H
Refrigerant Type : R448AAWEF Value : 3.15
CS161-193X110 START CAPACITOR
CAPACITOR,START,161 – 193 MFD,110V

Type two, dry, electrolytic, non-polarized, types for intermittent duty in AC motors and compressors, standard dual blade terminals
Industry standard case sizes
Made at Supco in Nanchang. Jiangxi, China
Moisture and oil resistant molded phenolic resin or plastic material
Non-PCB biodegradable synthetic oil, used where starting torques must be higher in relation to running torques
Application Motors and Compressors
Outside Diameter 1-7/16 in
SF9644 COUPLER, 1/4" FEMALE FLARE X (3) 1/4" MALE FLARES
Connector with two, ¼" male flares, one with core and cap in a 'U' shape. At the side is a ¼" female flare with depressor tip, and opposite that is an additional ¼" male flare.

Features/Benefits

¼" female flare with depressor tip on side and opposite is an additional ¼" male flare
Two ¼" male flares, one with core and cap, in a U shape
DP901203 CONTACTOR 90A 120V 3 POLE
CONTACTOR, 3 PL, BX LUG, 120A, 120V, 90A

Complete competitive cross-reference available
Economically priced
Interchangeable mounting with many competitive contactors
Silver cadmium oxide contacts
Space saving dimensions allow for smaller panels and more wiring room
Low Drop Out Voltage Making them Ideal for Any Air Conditioning Heating and Refrigeration


WE CARRY PARTS FOR ALL THE FOLLOWING MANUFACTURERS

Company Directory

Loading…


    Shop Grid Product
    No results found for ''. Showing results for ''.
    Drag building blocks here to customize the header for "" category.

    No product defined

    No product defined in this category.

    No results

    No results for "" in category "".

    Click 'New' in the top-right corner to create your first product.